ADLINK HSL-AI16AO2-M-VV/-AV User Manual
Page 116
![background image](/manuals/733479/116/background.png)
HSL Function Library
103
@ Argument
card_ID: Specifies the HSL master card index. Typically, the sys-
tem assigns the board index sequence. The index starts from 0.
connect_index: For PCI-7851, the valid value is 0. For PCI-
7852 and PMC-7852/G, the valid value is 0 or 1.
slave_No: Specifies the slave module with slave index that wants
to perform this function. The valid value is 1 to 63.
signal_range: The single range of analog input setting.
For HSL-AI16AO2-M-VV
0: ± 1.25 V
1: ± 2.5 V
2: ± 5 V
3: ± 10 V
For HSL-AI16AO2-M-AV
0: ± 5 mA
1: ± 10 mA
2: ± 20 mA
3: ± 20 mA
*signal_range: Reads back the single range of analog input
setting.
For HSL-AI16AO2-M-VV
0: ± 1.25 V
1: ± 2.5 V
2: ± 5 V
3: ± 10 V
For HSL-AI16AO2-M-AV
0: ± 5 mA
1: ± 10 mA
2: ± 20 mA
3: ± 20 mA
*mode: 0: differential type; 1: single-ended input.