SYMPTOM

Burner fails to light

Burner lights but goes out
when automatic control valve
button is released

Maximum burn rate is low

TROUBLESHOOTINg

WARNING: Never attempt to service heater while it is connected

to propane/LP supply, operating, or hot. Severe burns can occur.

POSSIBLE CAUSE

1. Propane/LP supply valve

closed on propane/LP cyl-
inder

2. Blockage in burner/orifice

elbow/hose and regulator
assembly

3. Battery not installed, battery

power low or battery not
installed correctly

1. Not enough warm up time

2. Low gas pressure

3. Thermocouple loose or

needs to be replaced

4. Automatic control valve

needs to be replaced

5. Thermocouple gap is too

great

1. Low gas pressure

2. Low fuel supply

3. Restriction in burner/orifice

elbow/hose and regulator
assembly

REMEDY

1. Open propane/LP supply

valve slowly

2. Clean burner/replace orifice

elbow/hose and regulator
assembly

3. Install new alkaline battery

in electronic ignitor. Verify
battery is installed correctly.
See page 14

1. Relight, hold automatic

control valve button in 30
seconds

2. Check propane/LP cylinder

for proper gas supply

3. Tighten connection or re-

place thermocouple

4. Replace automatic control

valve assembly

5. Maintain 0.17" gap between

tip of thermocouple and
emitter material

1. Check gas supply; check

regulator output

2. Consult propane/LP gas

supplier

3. Clean burner/replace orifice

elbow/hose and regulator
assembly

Advertising