WARNING: This appliance,

when installed must be electri-

cally grounded in accordance

with local code or in the ab-

sence of local code, with the

current National Electric Code,

ANSI/NFPA 70, or the Canadian

Electric Code, CSA C22.1.

HIGH ALTITUDE INSTALLATION

Your DESA Heating, LLC direct-vent fireplace
has been tested and approved in the USA
for elevations from 0-2,000 feet (610 m) and
in Canada at elevations from 0-4,500 feet
(1,372 m).

VENTING INSTALLATION

Continued

9-Volt.
Alkaline.
Battery

Receiver

Terminal.
Wires

Battery.Clip

Figure 15 - Attaching Alkaline Battery to

Receiver

When installing a non-high altitude fireplace
at an elevation above 2,000 feet (610 m) (in
the USA), you may need to decrease the input
rating by changing the existing burner orifice
to a smaller size. Reduce input 4% for each
1,000 feet (305 m) above sea level. Check
with your local gas company for proper orifice
size identification.
When installing this fireplace in Canada at an
elevation above 4,500 feet (1,372 m), Check
with.local.or.provincial.code.authorities.
Consult.your.local.gas.company.to.help.deter-
mine the proper orifice for your location.
For.assistance.with.any.high.altitude.installa-
tion contact DESA Heating, LLC’s Customer
Service.Department.at.1-866-67-6040.

INSTALLING OPTIONAL CONTROLS

INSTALLING OPTIONAL WALL
MOUNT SWITCH - GWMS2

1.. Connect.one.terminal.of.15.foot.wire.from.

wall.switch.to.male.connector.on.high.limit.
harness..Connect.remaining.wire.terminal.
to.TH.terminal.on.valve..Make.sure.that.
wire.terminals.are.in.positions.on.unit.as.
pictured.in.Figure.14..If.wires.are.not.con-
nected.as.shown.switch.will.not.work.

.. Route.15.foot.wire.through.hole.openings.

with.bushings.provided.on.either.side.of.
fireplace cabinet.

3.. Connect. one. bare. wire. end. to. each. of.

terminals.of.GWMS.wall.switch.

4.. Install.wall.switch.and.cover.in.wall.

IMPORTANT:.Do.not.use.any.other.wire.than.
that.provided.with.GWMS.wall.switch.kit..Do.
not.exceed.15.feet.of.distance.from.valve.con-
nection. Using wire of higher gauge or turns
or.exceeding.minimum.distance.will.increase.
resistance.at.control.valve.causing.unreliable.
performance of fireplace controls.

INSTALLING OPTIONAL WIRELESS
HAND-HELD REMOTE CONTROL
MODEL HRC100

Installing Remote Receiver
1.. Open.bottom.louver.and.locate.switch.

bracket.on.right.side.

.. Locate. battery. clip. mounted. on. back. of.

receiver.. Slide. a. 9-volt. alkaline. battery.
(not.included).through.clip.

3.. Attach. terminal. wires. to. battery. (see.

Figure.15).

Remote Receiver

or Wall Switch to

Terminal Marked “TH”

Wire Harness From

High Limit Switch

Male Connector to

Remote Receiver

or Wall Switch

Figure 14 - Connecting Remote Receiver

or Wall Switch to the Gas Control Valve