FIREPLACE INSTALLATION

Figure 22 - External Regulator with Vent

Pointing Down (Propane/LP Only)

Propane/LP.Supply.Tank

External.
Regulator.
with.Vent.
Pointing.
Down

CAUTION: Use only new,

black iron or steel pipe. Inter-

nally-tinned copper tubing may

be used in certain areas. Check

your local codes. Use pipe of

1/2" diameter or greater to allow

proper gas volume to fireplace.

If pipe is too small, undue loss

of volume will occur.

Installation.must.include.an.equipment.shutoff.
valve, union and plugged 1/8" NPT tap. Locate
NPT.tap.within.reach.for.test.gauge.hook.up..
NPT tap must be upstream from fireplace
(see.Figure.3).

CHECK GAS TYPE

Use only the correct type of gas (natural or
propane/LP).. If. your. gas. supply. is. not. the.
correct gas type, do not install fireplace. See
dealer where you purchased your fireplace for
proper gas type fireplace or tro purchase gas
conversion.kit.(see.Accessories, page 31).

INSTALLING GAS PIPING TO
FIREPLACE LOCATION

WARNING: A qualified

service person must connect

fireplace to gas supply. Follow

all local codes.

CAUTION: For propane/LP

units, never connect fireplace

directly to the propane/LP supply.

This heater requires an external

regulator (not supplied). Install

the external regulator between the

fireplace and propane/LP supply.

Installation Items Needed
Before installing fireplace, make sure you
have.the.items.listed.below.
•. external.regulator.(supplied.by.installer)
•. piping.(check.local.codes)
•. sealant.(resistant.to.propane/LP.gas)
•. equipment.shutoff.valve.*
•. test.gauge.connection.*
•. sediment.trap
• tee joint
•. pipe.wrench
• approved flexible gas line with gas connec-

tor.(if.allowed.by.local.codes)

* A CSA design-certified equipment shutoff
valve.with.1/8".NPT.tap.is.an.acceptable.al-
ternative.to.test.gauge.connection..Purchase.
the CSA design-certified equipment shutoff
valve.from.your.retailer.
For propane/LP connection only, installer
must. supply. an. external. regulator.. External.
regulator.will.reduce.incoming.gas.pressure..
You.must.reduce.incoming.gas.pressure.to.
between.11".and.14".of.water..If.you.do.not.
reduce incoming gas pressure, fireplace
regulator.damage.could.occur..Install.external.
regulator.with.vent.pointing.down.as.shown.in.
Figure...Pointing.vent.down.protects.it.from.
freezing rain or sleet.

Figure 23 - Gas Connection

CSA Design-Certified
Equipment.Shutoff.Valve.
with.1/8".NPT.Tap*

3".Minimum

Approved.
Flexible.
Gas.Line

Cap. Pipe. Tee.Joint
.

Nipple

Sediment.Trap/Drip.Leg

Natural.-.From.
Gas.Meter.(5.5".
W.C..to.10.5".W.C..
Pressure)
Propane/LP.From.
External.Regulator.
(11".W.C..to.14".
W.C..Pressure)

* The CSA design-certified equipment shutoff
valve.may.be.supplied.with.the.appliance.or.
you.can.purchase.it.from.your.retailer.