Installation, Air for combustion and ventilation – Desa VN1000BTA User Manual

Page 7

Advertising
background image

www.desatech.com

110720-01K

7

ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or

ducts. You must provide two permanent openings:

one within 12" of the ceiling and one within 12"

of the floor. Connect these items directly to the

outdoors or spaces open to the outdoors. These

spaces include attics and crawl spaces. Follow the

National Fuel Gas Code, ANSI Z223.1/NFPA 54,

Section 5.3, Air for Combustion and Ventilation for

required size of ventilation grills or ducts.
IMPORTANT:

Do not provide openings for inlet

or outlet air into attic if attic has a thermostat-

controlled power vent. Heated air entering the attic

will activate the power vent.

Or

Remove

Door into

Adjoining

Room,

Option 3

Ventilation Grills

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills

into Adjoining

Room,

Option 1

Figure 2 - Ventilation Air from Inside

Building

Outlet

Air

Ventilated

Attic

Outlet

Air

Inlet

Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

Figure 3 - Ventilation Air from Outdoors

AIR FOR COMBUSTION

AND VENTILATION

Continued

INSTALLATION

NOTICE: This heater is intended

for use as supplemental heat. Use

this heater along with your primary

heating system. Do not install this

heater as your primary heat source.

If you have a central heating system,

you may run system’s circulating

blower while using heater. This will

help circulate the heat throughout

the house. In the event of a power

outage, you can use this heater as

your primary heat source.

WARNING: A qualified ser-

vice person must install heater.

Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or pro-

pane/LP). If your gas supply is not the correct gas

type, do not install heater. Call dealer where you

bought heater for proper type heater.

This appliance is only for use with

the type of gas indicated on the rat-

ing plate. This appliance is not con-

vertible for use with other gases.

WARNING: This appliance

is equipped for (natural or pro-

pane/LP) gas. Field conversion

is not permitted.

INSTALLATION ITEMS

Before installing heater, make sure you have the

items listed below.

• for propane/LP gas, external regulator (supplied

by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• ground joint union

• sediment trap

• tee joint

• pipe wrench

• for natural gas, test gauge connection*

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 27.