WIRING DIAGRAM

Receiver

Black

On
Off

Remote

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH TP

SERVICE HINTS

When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
• propane/LP gas supply may be low
You may feel your gas pressure is too low. If so,

contact your local propane/LP gas supplier.

TECHNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA

Heating Productsʼ Technical Service Department at

1-866-672-6040. When calling, please have your

model and serial numbers of your heater ready.
You can also visit DESA Heating Productsʼ techni-

cal service web site at www.desatech.com.

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized dealers of this product. If

they canʼt supply original replacement part(s),

call DESA Heating Productsʼ Technical Service

Department at 1-866-672-6040.
When calling DESA Heating Products, have

ready
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• type of gas used (propane/LP or natural gas)
• purchase date
Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized dealers of this product. If they

canʼt supply original replacement part(s) call

DESA Heating Products at 1-866-672-6040 for

referral information.
When calling DESA Heating Products, have

ready
• model number of your heater
• the replacement part number

SPECIFICATIONS

VGL18PRA

VGL18NRA

VGL24PRA

VGL24NRA

VGL30PRA

VGL30NRA

Btu (Variable)

21,000/30,000

21,000/30,000

Type Gas

Propane/LP

Natural Gas

Ignition

Electronic

Electronic

Manifold Pressure

8.0" W.C.

3.5" W.C.

Inlet Gas Pressure (in. of water)
Maximum

14"

10.5"

Minimum*

11"

5"

* For the purpose of input adjustment