2.5.5 Relay Hold Schedule

Default setting in step 3 is 0 (Hold schedules are OFF).

This program sequence sets up schedules to automatically activate and deactivate relays 1 and 2 on
the control board. Four schedules can be programmed, each of which can be assigned to the desired
relay(s). These schedules can be independently turned on or off after they have been programmed.

1. Press * 3 5 and enter the MASTER CODE. [ * 3 5 _ _ _ _ (beep)]

2. Enter a schedule number (1, 2, 3 or 4) then press *. [ _ * (beep)]

3. Press 0 * to turn the schedule off, OR press 1 * to turn the schedule on. [ _ * (beep)]

You can terminate here (step 11) if you have previously programmed the schedules and
only ON / OFF is desired.

4. Enter the begin time hour (01-12) and minutes (01-59) then press *. [ _ _ _ _ * (beep)]

5. Press 0 * for AM, OR press 1 * for PM. [ _ * (beep)]

6. Enter the end time hour (01-12) and minutes (01-59) then press *. [ _ _ _ _ * (beep)]

7. Press 0 * for AM, OR press 1 * for PM. [ _ * (beep)]

8. Enter the days of the week that the hold open schedule is to be active then press *.

[ _ _ _ _ _ _ _ * (beep)]
Sun = 1, Mon = 2, Tue = 3, Wed = 4, Thu = 5, Fri = 6, Sat = 7.
You can enter up to 7 numbers here (1-7). For example, for the hold open schedule to
be active only on Saturdays and Sundays, enter 1 7. The order of the numbers is not
important; 17 is the same as 71.

9. Enter the relay number(s) that the schedule will apply to, then press *. [ _ * (beep)]

You can enter a single relay number here, or both relay numbers (1 & 2).

10. Repeat steps 2 through 9 to program the other time zones.

11. Press 0# TOGETHER to end. [0# (beeeeeep)]