Storage, Servicing, Operating instructions – Desa SPC-54PHW User Manual

Page 8

Advertising
background image

www.desatech.com

114144-01C

8

3. To match light pilot, rotate the viewing hole

cover and apply flame to the pilot burner while

holding knob in for 20 seconds or until pilot

remains lit when knob is released.

4. Set the heat level.

a) Press and turn control knob to the HIGH

position. Burner will light immediately.

b) Press and turn control knob to the desired

heat level. Note: While in use, burner

flame should be mainly blue in appearance

with a small amount of yellow.

IMPORTANT:

Smoke and odor (not a gas odor)

emission may occur in the first 15 minutes of use.

Run heater at high setting for at least 15 minutes

to eliminate this problem.

WARNING: If you smell gas

while in use, immediately press

and turn control knob to the

"OFF" position to shutdown

heater.

STOP

1. Press and turn control knob to the PILOT

position. Burner will extinguish but pilot will

stay on.

2. To extinguish pilot, press and turn control

knob to the OFF position.

3. Turn off gas supply.
4. Do not attempt to relight the heater for 5

minutes after propane/LP cylinder valve has

been closed.

RESTART HEATER

1. Turn gas control knob to the OFF position.
2. Wait 5 minutes.
3. Restart following Start procedure.

STORAGE

1. Allow at least 45 minutes for heater to cool

down after using.

2. Store heater upright in a sheltered area away

from inclement weather and dust.

3. If desired, cover heater after heater has

cooled.

4. If heater is not to be used for an extended period

of time, disconnect and remove propane/LP

gas cylinder and store in accordance with the

Standard for Storage and Handling of Liquefied

Petroleum Gases, ANSI/INFPA 58.

SERVICING

To assure safety, proper function and longevity

of the heater, regular maintenance is required.

The frequency of maintenance will depend on the

usage of the unit. Review the following concern-

ing the criteria for a properly functioning heater.

Failing to follow proper, regular maintenance will

void warranty.
A hazardous condition may result if a heater is

used that has been modified or is not functioning

properly. When the heater is working properly:
• The flame is contained within the heater.
• The flame is essentially blue with perhaps some

yellow tipping.

• There is no strong disagreeable odor, eye burn-

ing or other physical discomfort.

• There is no smoke or soot internal or external

to the heater.

• There are no unplanned or unexplained shut

downs of the heater.

The parts lists and wiring diagram show the heater

as it was constructed. Do not use a heater which is

different from that shown. In this regard, use only

the hose, regulator and cylinder connection fitting

(called a POL fitting) supplied with the heater.

IMPORTANT:

Do not use alternates. For this

heater, the regulator must be set as shown in Speci-

fications, page 2. If there is any uncertainty about

the regulator setting, have it checked.

OPERATING INSTRUCTIONS

Continued

Advertising