Local codes, Product identification, Unpacking – Desa VTN25R ES User Manual

Page 4: Product features, Safety information

Advertising
background image

www.desatech.com

113261-01A

4

5. This heater needs fresh, outside air ventilation

to run properly. This heater has an Oxygen

Depletion Sensing (ODS) safety shutoff

system. The ODS shuts down the heater if

not enough fresh air is available. See Air for

Combustion and Ventilation, page 5.

6. Keep all air openings in front and bottom of

heater clear and free of debris. This will insure

enough air for proper combustion.

7. If heater shuts off, do not relight until you

provide fresh, outside air. If heater keeps

shutting off, have it serviced.

8. Do not run heater

• where flammable liquids or vapors are used

or stored

• under dusty conditions

9. Do not use heater if any part has been under

water. Immediately call a qualified service

technician to inspect the room heater and to

replace any part of the control system and any

gas control which has been under water.

10. Turn off heater and let cool before servicing.

Only a qualified service person should service

and repair heater.

11. Operating heater above elevations of 4,500

feet (1372 m) could cause pilot outage.

12. To prevent performance problems, do not

use propane/LP fuel tank of less than 100

psi (690 kPa) capacity.

13. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If

heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

14. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use heater with care. Follow all local

codes. In the absence of local codes, use the latest

edition of The National Fuel Gas Code, ANSI

Z223.1/NFPA 54

*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

SAFETY INFORMATION

Continued

Figure 1 - Infrared Tower Heater

UNPACKING

1. Remove heater from carton.
2. Remove all protective packaging applied to

heater for shipment.

3. Check heater for any shipping damage. If

heater is damaged, promptly contact the dealer

to where you bought heater.

PRODUCT FEATURES

SAFETY DEVICE

This heater has a pilot with an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS/pilot is a required feature for vent-free room

heaters. The ODS/pilot shuts off the heater if there

is not enough fresh air.

IGNITION SYSTEM

This heater has an electronic ignitor to light heater

fuel supply, which requires a AAA battery.

THERMOSTATIC HEAT CONTROL

Your unit is thermostatically controlled when heat-

er and remote control are set to the proper modes.

This results in the greatest heater comfort.

PRODUCT

IDENTIFICATION

Electronic
Ignitor

Grill

Plaque
(behind
Grill)

On/Pilot/Off Knob

Manual/Auxiliary
Knob

Advertising
This manual is related to the following products: