Wiring diagram, Cleaning and maintenance – Desa FDCFTP User Manual

Page 29

Advertising
background image

www.desatech.com

111244-01F

29

Figure 56 - Injector Holder On Outlet

Burner Tube

Burner
Tube

Injector
Holder

Primary Air
Inlet Holes

3. Blow air through the ports/slots and holes in

the burner.

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint, or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

two inches from where the pilot flame comes out

of the pilot assembly (see Figures 57 or 58 depend-

ing on model). With the unit off, lightly blow air

through the air inlet hole. You may blow through a

drinking straw if compressed air is not available.

CLEANING AND

MAINTENANCE

Continued

Figure 57 - Pilot Inlet Air Hole

(Propane/LP Gas)

Pilot Assembly

Pilot Air Inlet Hole

Pilot Assembly

Pilot Air
Inlet Hole

Figure 58 - Pilot Inlet Air Hole

(Natural Gas)

WIRING DIAGRAM

(Remote-Ready Models Only)

Switch

Black

Auto

Of

f

On

Red

Red

White

Thermopile

Gas Control

TPTH

TH

TPTH

TP

LOG SET

• If you remove one-piece log set for cleaning,

refer to page 21, for placement instructions.

• Replace log set if broken or chipped (dime-sized

or larger).

CABINET

Air Passageways
Use a vacuum cleaner or pressurized air to

clean.
Exterior
Use a soft cloth dampened with a mild soap

and water mixture. Wipe the cabinet to remove

dust.

Advertising
This manual is related to the following products: