WARNING: Turn off log set and let cool before servicing. Only a

qualified service person should service and repair log set.

Note:

All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Poor fuel quality

2. Fireplace venting system not

drafting properly

3. Excessive flame impingement

or blockage

4. Improper fuel/air mixture

5. Excessive gas supply/pressure

1. Passage of air/gas across ir-

regular surfaces

1. Incorrect gas supply or

pressure

2. Blocked burner orifice or

burner manifold ports

3. Improper burner orifice size

REMEDY

1. Contact local natural gas

company

2. Adjust damper wide open

and/or have fireplace and vent-

ing professionally cleaned and

checked

3. Separate the logs to allow more

flame passage

4. Remove any foreign items from

the flame pattern and/or check

for proper orifice sizing

5. Preheat flue in very cold

weather

1. Relieve any tight bends or

kinks in gas supply line

1. Check for proper gas supply

pressure

2. Free burner orifice and mani-

fold ports of any burrs, paint,

or other blockage

3. Verify proper burner orifice

sizing (see Figure 2, page 5)

OBSERVED PROBLEM

Log set is smoking/sooting

excessively (Note: It is natural

and unavoidable for vented gas

log sets to produce moderate

levels of carbon (soot) where

flames contact the logs.)

Burner is excessively noisy

(Note: The movement and com-

bustion of gas will create low,

unavoidable levels of noise.)

Burner flame is too low or too

high