INSTALLATION

WARNING: Before installing

in a solid fuel burning fireplace,

the chimney flue and firebox

must be cleaned of soot, creo-

sote, ashes and loose paint by a

qualified chimney cleaner. Creo-

sote will ignite if highly heated.

A dirty chimney flue may create

and distribute soot within the

house. Inspect chimney flue for

damage. If damaged, repair flue

before operating appliance.

NOTICE: Installation, service, and

repair of this appliance must be

performed by a qualified installer,

service agency, company or

gas supplier experienced with

this type of gas appliance. Only

factory authorized components

listed in these instructions may

be used in accordance with the

manufacturer’s instructions and

all codes and requirements of

the authority having jurisdiction.

Any modifications to this kit, or

use of unauthorized components

or accessory items will void the

manufacturer’s warranty, and may

result in a hazardous condition.

FLUE OPENING SPECIFICATIONS

Note:

This vented appliance must be installed only

in a solid-fuel burning fireplace with a working flue

and constructed of noncombustible material.
The charts in Figure 2 indicate technical information

regarding the installation of your gas log set. Please

make sure that all of the specifications shown are

applicable before installation is attempted.
The fireplace must include a working flue and

venting system with the minimum openings shown

in the Figure 2.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not

natural gas, you must install ON/OFF Safety

Valve/Pilot Kit (see Accessories, page 13). Call

dealer where you bought log set.
If the fireplace does not have a gas supply shutoff

valve, one must be installed.

VENTING SPECIFICATIONS FOR
INSTALLATION

The fireplace chimney flue and vent must be draft-

ing properly. To check the vent for proper drafting:

Light a tightly rolled newspaper on one end and

place it at the inside front edge of the fireplace.

Observe the smoke and be sure the vent is properly

drawing it up the chimney. If the smoke spills out

into the room, extinguish the flame and remove any

obstruction until proper venting is achieved.
The chimney flue must remain open a minimum

of 3" at all times during the operation of this

log set.

BURNER ORIFICE

LOG

SIZE

NATURAL

IN.

NUM.

18"

.120

31

24"

.140

28

MINIMUM FIREBOX SIZES

MODEL FRONT

WIDTH

BACK

WIDTH*

DEPTH HEIGHT

SMS18

28"

18"

16"

18"

SMS24

32"

24"

16"

18"

Model

Burner

Descrip-

tion

Btu Input

Natural

Gas

Minimum

Vent

Opening

SMS18 18" Ramp

60,000

8" dia.

SMS24 24" Ramp

80,000

8" dia.

*At depth indicated

FUEL INLET PRESSURE

SPECIFICATIONS (W.C.)

Min.

Max.

NG

5.5"

10.5"

LP

11"

13"

Figure 2 - Technical Information Charts