Local codes, Safety information – Desa VSGF36NRA User Manual

Page 4

Advertising
background image

www.desatech.com

116746-01A

4

1. This appliance is only for use with the type of

gas indicated on the rating plate. This appliance

is not convertible for use with other gases.

2. Do not place propane/LP supply tank(s) in-

side any structure. Locate propane/LP supply

tank(s) outdoors (propane/LP units only).

3. If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use

any phone in your building

• immediately call your gas supplier from a

neighborʼs phone. Follow the gas supplierʼs

instructions

• if you cannot reach your gas supplier, call

the fire department

4. This fireplace shall not be installed in a bed-

room or bathroom.

5. Do not use this fireplace as a wood-burning

fireplace. Use only the logs provided with the

fireplace.

6. Do not add extra logs or ornaments such as

pine cones, vermiculite or rock wool. Using

these added items can cause sooting. Do not

add lava rock around base. Rock and debris

could fall into the control area of fireplace.

7. To prevent the creation of soot, follow the

instructions in Cleaning and maintenance,

page 25.

8. Before using furniture polish, wax, carpet

cleaner or similar products, turn heater off. If

heated, the vapors from these products may

create a white powder residue within burner

box or on adjacent walls or furniture.

9. This fireplace needs fresh air ventilation to run

properly. This fireplace has an Oxygen Deple-

tion Sensing (ODS) safety shutoff system. The

ODS shuts down the fireplace if enough fresh

air is not available. See Air for Combustion

and Ventilation, page 7. If fireplace keeps

shutting off, see Troubleshooting, page 27.

10. Do not run fireplace

• where flammable liquids or vapors are used

or stored

• under dusty conditions

11. Do not use this fireplace to cook food or burn

paper or other objects.

SAFETY INFORMATION

Continued

12. Do not use fireplace if any part has been

exposed to or under water. Immediately call

a qualified service technician to inspect the

fireplace and to replace any part of the control

system and any gas control which has been

under water.

13. Do not operate fireplace if any log is broken.

Do not operate fireplace if a log is chipped

(dime-sized or larger).

14. Turn fireplace off and let cool before servicing.

Only a qualified service person should service

and repair fireplace.

15. Operating fireplace above elevations of 4,500

feet could cause pilot outage.

16. To prevent performance problems in propane/LP

units, do not use propane/LP fuel tanks of less

than 100 lbs. capacity (propane/LP units only).

17. Provide adequate clearances around air

openings.

LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence of local codes, use the lat-

est edition of The National Fuel Gas Code ANSI

Z223.1/NFPA 54*.
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

Note:

Where listed vented decorative logs are

required, thermostat operation is not permitted.

State of Massachusetts: The installa-

tion must be made by a licensed plumber

or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural

gas-fired supplemental room heaters shall

provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for

bedroom and bathroom installation in the

Commonwealth of Massachusetts.