Local codes, Product features, Locating firebox – Desa VCM-50U User Manual

Page 4: Local codes locating firebox

Advertising
background image

www.desatech.com

122274-01F

4

State of Massachusetts: The installation
must be made by a licensed plumber
or gas fitter in the Commonwealth of
Massachusetts.
Sellers of unvented propane or natural
gas-fired supplemental room heaters
shall provide to each purchaser a copy of
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for
bedroom and bathroom installation in
the Commonwealth of Massachusetts.

ProdUCT FeATUres

OpERATION

This firebox is designed for use with approved
ANSI Z21.11.2 decorative type unvented room
heaters. (Physical size limitations apply. Refer
to minimum firebox requirements supplied
with log heater.) It requires no outside vent-
ing or chimney making installation easy and
inexpensive.

loCAl Codes

loCATINg FIreBoX

pLANNING

Plan where you will install the firebox. This will
save time and money later when you install
the firebox. Before installation, consider the
following:
1. Where firebox will be located. Allow for

wall and ceiling clearances (see Installa-
tion Clearances
, page 11).

2. Everything needed to complete installation.
3. These models CANNOT be installed in

a bedroom unless maximum Btu rating
of installed vent-free log set is less than
10,000 Btu/hr.

4. Proper air for combustion and ventilation

(page 8).

Install and use firebox with care. Follow all
local codes. In the absence of local codes,
use the latest edition of The National Fuel Gas
Code ANSI Z223.1/NFPA 54
*. Firebox must
be electrically grounded in accordance with
the National Electrical Code, ANSI/NFPA70
(latest edition).
*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269