Absolute maximum ratings, Gbic-1250 long distance series, Recommended operating conditions – Delta Electronics GBIC-1250D5VR User Manual

Page 2

Advertising
background image

GBIC-1250 Long Distance Series

DELTA ELECTRONICS, INC.

2 01/23/2008

Rev. 0F

www.deltaww.com

Absolute Maximum Ratings

Parameter Symbol

Min.

Typ.

Max.

Unit

Notes

Storage Temperature

Ts

-40

85

ºC

Supply Voltage

V

CC

0 6 V

Recommended Operating Conditions

Parameter Symbol

Min.

Typ.

Max.

Unit

Notes

Ambient Operating Temperature

T

A

-5 70

Supply voltage

Vcc

3.15 / 4.75 3.3 / 5

3.45 / 5.25

V

Total Supply Current

I

S

300

mA

Data Output Load

R

DL

75


Transmitter Electro-Optical Performance Specifications:

(T

A

=-5 °C to 70 °C, V

CC

=3.15V to 3.45V or V

CC

=4.75V to 5.25V)

Parameter Symbol

Min.

Typ.

Max.

Unit

Note

Transmitter

Transmitter Differential Input Voltage

V

DT

0.5 2.4 V

1

Transmitter Disable Input-High

V

DISH

2

V

CC

+0.3

V

Transmitter Disable Input-Low

V

DISL

0 0.8 V

Transmitter Fault Pull up Resistor

R

TX_FAULT

4.7 10 kΩ 2

Transmitter Fault Output-High

V

TXFH

2

V

CC

+0.3

V 2

Transmitter Fault Output-Low

V

TXFL

0 0.8 V

2

Receiver

Receiver Differential Output Voltage

V

DR

0.35

2

V

3

Receiver LOS Load

R

RXLOS

4.7 10 kΩ 2

LOS Output Voltage-High

V

LOSH

2

V

CC

+0.3

V 2

LOS Output Voltage-Low

V

LOSL

0 0.8 V

2

Output Dara Rise / Fall Time

t

r

/ t

f

220

psec 4

Notes:
1. Internally AC coupled and terminated to 150Ohm differential load.
2. Pull up to V

CC

on host Board

3. Internally AC coupled, but requires a 150Ohm differential termination at or internal to Serializer/

Deserializer.

4. These are 20%~80% values.