Interpretation by host reference, Gbic timing parameters for gbic management, Unit conditions – Delta Electronics GBIC-1250D5VR User Manual

Page 6: Gbic-1250 long distance series

Advertising
background image

GBIC-1250 Long Distance Series

DELTA ELECTRONICS, INC.

6 01/23/2008

Rev. 0F

www.deltaww.com

GBIC module definition parameters

Module

Definition

MOD_DEF(0)

Pin 4

MOD_DEF(1)

Pin 5

MOD_DEF(2)

Pin 6

Interpretation by host Reference

0

NC

NC

NC

GBIC not present clause

1 NC NC

TTL

LOW

Copper Style 1 or Style 2 connector, 1.0625 Gbd,
100-TW-EL-S or 100-TP-EL-S, active
inter-enclosure connection and IEEE802.3
1000BASE-CX

2

NC TTL

LOW NC

Copper Style 1 or Style 2 connector, 1.0625 Gbd,
100-TW-EL-S, or 100-TP-EL-S, active or passive
intra-enclosure connection

3

NC

TTL LOW

TTL LOW Optical LW, 1.0625 Gbd 100-SM-LC-L

4

TTL LOW

SCL

SDA

Serial module definition protocol

5 TTL

LOW NC TTL

LOW

Optical SW, 1.0625 Gbd 100-M5-SN-I or
100-M6-SN-I

6

TTL LOW

TTL LOW

NC

Optical LW, 1.0625 Gbd 100-SM-LC-L and similar
to 1.25 Gbd IEEE802.3z 1000BASE-LX, single
mode

7

TTL LOW

TTL LOW

TTL LOW

Optical SW, 1.0625 Gbd 100-M5-SN-I or
100-M6-SN-I and 1.25 Gbd, IEEE 802.3z,
1000BASE-SX

GBIC timing parameters for GBIC management

Parameter Symbol

Min. Max. Unit Unit

Conditions

TX_DISABLE assert time

t_off

10

µsec

Rising edge of TX_DISABLE to fall of output signal
below 10% of nominal

TX_DISABLE negate
time

t_on 1

mec

Falling edge of TX_DISABLE to rise of output
signal above 90% of nominal

Time to initialize,
includes reset of
TX_FAULT

t_init

300 msec

From power on or hot plug fter V DD T > 4.75 volts
or From negation of TX_DISABLE during reset of
TX_FAULT.

TX_FAULT from fault to
assertion

t_fault 100

µsec

From occurrence of fault (out-put safety violation or
V DD T < 4.5 volts)

TX_DISABLE time to
start reset

t_rest 10

µsec TX_DISABLE HIGH before TX_DISABLE set LOW

RX_LOS assert delay

t_loss_on

100

µsec

From detection of loss of signal to assertion of
RX_LOS

RX_LOS negate delay

t_loss_off

100

µsec

From detection of presence of signal to negation of
RX_LOS

Advertising
This manual is related to the following products: