Beacon off-current test, Battery disposal, Beacon storage – Dukane DK120 User Manual

Page 21: Beacon overhaul, Figure 21. rbb label placement, Figure 22. beacon off-current test set-up

Advertising
background image

03-TM-0037 REV 13

Page 21 of 24

WARNING

DO NOT RECHARGE, DISAS-
SEMBLE, HEAT ABOVE 160°F (71°C)
OR INCINERATE. THERE IS A RISK
OF BATTERY FIRE, EXPLOSION,
AND BURNS.

6.8. BATTERY DISPOSAL.

Dispose of battery in accordance with all local,
state and federal regulations. Dispose of batteries
promptly, keep away from children.

6.9. BEACON STORAGE.

When long term storage of a beacon is required,
the beacon should be stored in the original
shipping container (or equivalent). Make sure it
is stored in a cool dry environment. The beacon
should be stored without battery.

6.10. BEACON OVERHAUL.

The acoustic characteristics of the beacon shall
be checked after 18 years of service to insure
that the beacon it is still in compliance with FAA
regulations.

6.7. BEACON OFF-CURRENT TEST.

Connect test leads as shown in Figure 22 and
check for current leakage between battery and
beacon body. The battery OFF current must be
less than 3 microamperes. Beacons with greater
than 3 microamperes OFF current should be
taken out of service immediately.

Figure 22. Beacon Off-Current Test

Set-Up

Figure 21. RBB Label Placement

Advertising
This manual is related to the following products: