Check gas supply at
burner

Ignition System / Gas Ignition

YES

Check plug top fuse and
replace if necessary

Check polarity and earth
continuity of supply point

Check earth continuity
of appliance

Ignitor does not spark

Check fitting
of burners

Check position of the
electrode

Check by pass simmer
adjusted

Light burner manually

Check continuity from 'N' on the
mains connector block and "O" on
the ignitor unit

Check continuity from 'L' on the
mains connector block and the
taps ignition switches

Check continuity from ignition
switches connector to ignitor unit

Check continuity from the tip of
each electrode to the terminals 1
to 4 on the ignitor unit

Check for breaks in the insulation
of the HT leads

NO

Change the ignitor unit

Change the taps ignition
switches