Sync polarity jumpers

The interface is factory configured for the output sync to follow

the input sync. To force positive or negative sync, reconfigure

the jumper as follows:
1

.

Locate J9, J20, and J21 on the printed circuit board.

2

.

For sync follow (output sync polarity identical to the
input sync)

, ensure that the jumper is removed from

jumper block J21.

3

.

For positive or negative sync

, ensure that a jumper is

installed in jumper block J21 and configure J9 and J20 as

follows:
a

.

Horizontal sync

For positive sync

, install a jumper in block J9.

For negative sync

, remove the jumper from block J9.

b

.

Vertical sync

For positive sync

, install a jumper in block J20.

For negative sync

, remove the jumper from block J20.