RGB 201 Rxi Universal Interface • Installation and Operation

2-9

Rack mounting

UL guidelines for rack mounting

The following Underwriters Laboratories (UL) guidelines are

relevant to the safe installation of these products in a rack:
1

.

Elevated operating ambient temperature —

If the unit

is installed in a closed or multi-unit rack assembly, the

operating ambient temperature of the rack environment

may be greater than room ambient temperature. Therefore,

install the equipment in an environment compatible with

the maximum ambient temperature (Tma: +122 °F, +50 ° C)

specified by Extron.

2

.

Reduced air flow —

Install the equipment in the rack

so that the equipment gets adequate air flow for safe

operation.

3

.

Mechanical loading —

Mount the equipment in the rack

so that uneven mechanical loading does not create a

hazardous condition.

4

.

Circuit overloading —

Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Give appropriate consideration to the

equipment nameplate ratings when addressing this

concern.

5

.

Reliable earthing (grounding) —

Maintain reliable

grounding of rack-mounted equipment. Pay particular

attention to supply connections other than direct

connections to the branch circuit (such as the use of power

strips).

Rack mounting procedure

1

.

If feet were installed on the bottom of the interface, remove

them.

2

.

Place the interface on one half of the 1U (one unit high,

19" wide) optional rack shelf (part #60-190-01). Align the

front of the interface with the front of the shelf, and align

the threaded holes on the bottom of the interface with the

holes in the rack shelf (figure 2-5).