Centering memory, Lcd display, Lcd screen backlight – Extron Electronics RGB 201 User Manual

Page 30: Scan rate indication, Centering indications, Installation and operation, cont’d

Advertising
background image

RGB 201 Rxi Universal Interface • Installation and Operation

Installation and Operation, cont’d

N

The centering controls have no mechanical limits to
rotation. When the minimum or maximum limit of
the control is reached, LCD indicates the horizontal or
vertical shift limit has been reached and the picture stops
moving on the screen.

Centering memory

Turning the centering knobs not only moves the images, but it

also stores the horizontal and vertical centering setting in the

interface’s memory. The interface recalls the centering settings

each time it detects a change in the input frequency. Centering

adjustments only need to be set once for an application because

the settings are saved even when the power is off.

LCD display

e

LCD display — The LCD displays the horizontal and vertical

scanning rates of the input signal and indicates the horizontal

and vertical centering status and limits.

LCD screen backlight

The LCD backlights for 15 seconds at power-up, and it remains

backlit as long as an input signal is present. To force the

backlight to remain off at all times except at power-up, set DIP

switch 6 (No Backlight) on the rear panel to On (up).

Scan rate indication

When the interface is powered on, the LCD lights for 15 seconds

while it determines whether an input sync signal is present. If

DIP switch 6 is set to On (up), the LCD lights for three seconds

only.
• If the interface does not detect an input sync signal,

the LCD goes dark and displays NO SIGNAL until the

interface receives an active sync signal.

• If the interface detects an input sync signal, the LCD

displays the horizontal and vertical scan rates (sync

frequencies) in the following format:

Hxxx.xxk

Vxxx.xHz

The first line shows the horizontal rate in kilohertz, and

the second line shows the vertical rate in Hertz.

Centering indications

While the vertical (

{

) or horizontal (

[

) centering (shift)

controls are being adjusted, the LCD displays H-SHIFT or

V-SHIFT. That message remains on the LCD (in place of the

scan rates) until the centering control has been inactive for

3 seconds.

2-18

Advertising
This manual is related to the following products: