Command / response table for sis commands, Command/response table for sis commands, Remote contr ol, cont’d – Extron Electronics RGB 201 User Manual

Page 36

Advertising
background image

RGB 201 R

xi Universal Interface • Remote Contr

ol

Remote Contr

ol, cont’d

3-4

Command/response table for SIS commands

Command

ASCII Command Response

Additional description

(host to switcher) (switcher to host)

Horizontal shift

Set horizontal shift

X@

H

Hph

X@]

Set horizontal shift value to

X@

(range -127 to +127).

Example

:

28H

Hph+028

]

Set horizontal shift value to +28.

Increment horizontal shift value

+H

Hph

X@]

Previous horizontal shift value +1 (shift right).

Decrement horizontal shift value

-H

Hph

X@]

Previous horizontal shift value -1 (shift left).

View horizontal shift value

H

X@]

Vertical shift

Set vertical shift

X@

/

Vph

X@

Set vertical shift value to

X@

(range -127 to +127).

Example

:

-5/

Vph-005

]

Set horizontal shift value to -5.

Increment vertical shift value

+/

Vph

X@]

Previous vertical shift value +1 (shift up).

Decrement vertical shift value

-/

Vph

X@]

Previous vertical shift value -1 (shift down).

View vertical shift value

/

X@]

View, information, part number, and firmware requests

Information request

I/i

Hph

X@

•Vph

X@

•Hrt

X$

•Vr

X$]

Example

Hph+028•Vph-005•Hrt48.400•Vrt60.000

]

Horizontal shift value +28; vertical shift value -5;
horizontal rate 48.4 kHz; vertical rate 60 Hz.

Request for part number

N/n

X^]

Example:

n

60-507-01

]

60-507-01 = RGB 201 Rxi.

Query software version

Q/q

X#]

Example:

q

1.23

]

Software version 1.23 (example only).

Advertising