F. Electrical Connection

WARNING

For All Models

1. Electrical connection must be hard-wired and must meet national, state, and

local electrical code requirements. Failure to meet these code requirements
could result in death, electric shock, serious injury, fire, or extensive damage
to equipment.

2. This unit requires an independent power supply. See the nameplate for

proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse
can result in a tripped breaker, blown fuses, or damage to existing wiring.
This could lead to heat generation or fire.

3.

THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could

result in death or serious injury.

4. Electrical connection must be made in accordance with the instructions on

the "WARNING" tag, provided with the pig tail leads in the junction box. See
Fig. 8.

Additional Warnings for Remote Air-Cooled Model

5.

THE REMOTE CONDENSER UNIT MUST BE GROUNDED. The power

supply and ground wire to the remote condenser unit are supplied from the
icemaker. See "II.G.5. Electrical Connection."

6. To reduce the risk of electric shock, make all remote condenser unit

connections before connecting the icemaker power supply.

7. On remote air-cooled model, the icemaker should have power for a minimum

of 4 hours prior to startup to prevent compressor damage.

• Usually an electrical permit and services of a licensed

electrician are required.

• The maximum allowable voltage variation is ±10

percent of the nameplate rating.

• On three phase models, the transformer's voltage tap

switch must be positioned to match incoming voltage

at startup. See Fig. 8.

CAUTION! On three phase models, connect the

highest incoming voltage supply ("stinger leg")

to the red power supply wire (red common wire

to the compressor).

• The opening for the power supply connection is 7/8"

DIA to fit a 1/2" trade size conduit.

Fig. 8

 WARNING

ELECTRICAL CONNECTION

THIS UNIT MUST BE GROUNDED
Failure to properly ground or wire
this unit could result in death,
serious injury, or severe damage to
the icemaker.
This unit must be connected to a
three-phase power source.
The transformer’s voltage tap switch
must be positioned to match incoming
voltage at startup.
See diagram below.

208-230/60/3

4A4807-010

JUNCTION BOX

208-230

V

BROWN

BLACK

L1

L3

RED

L2

208- 230V

208- 230V

KM-2100S_H3