Water-cooled condenser, Fig. 17 – Hoshizaki STACKABLE CRESCENT CUBER KM-2100SWH3 User Manual

Page 23

Advertising
background image

23

2. Water-Cooled Condenser
a) Connection to an Open Drain System
• Condenser water supply inlet is 1/2" female pipe thread (FPT). A minimum of 3/8" OD

copper tubing is recommended for the condenser water supply line.

• A condenser water supply line shut-off valve and drain valve should be installed.
• Condenser drain outlet is 3/8" FPT. A minimum of 3/8" OD hard pipe is recommended for

the condenser drain line. Drain line must be run separately.

• In some areas, a back flow preventer may be required in the cooling water circuit.

KM-2100SWH3
Connection to an Open Drain System

Condenser Water Supply Inlet 1/2" FPT

Icemaker Water Supply Inlet 1/2" FPT

Icemaker
Drain Outlet
3/4" FPT

Condensation
Drain Outlet
3/8" OD
Stainless
Tube

Condenser Drain Outlet 3/8" FPT

Bin Drain Outlet 3/4" FPT

Bin

Icemaker

Separate piping
to approved drain.
Leave a 2 inch
(5 cm) vertical air
gap between the
end of each pipe
and the drain.

Icemaker Water Supply Line Shut-Off Valve

Icemaker Water Supply Line Drain Valve

Condenser Water Supply Line Shut-Off Valve

Condenser Water Supply Line Drain Valve

Fig. 17

2 inch (5 cm)
air gap

Floor

Drain