Internal usb connector – HP AMS DL320 User Manual

Page 13

Advertising
background image

Server component identification 13

System LED and Color

Internal Health
LED Color

Status

Amber

DIMM in slot X has reached single-bit correctable
error threshold.

DIMM in slot X is in a pre-failure condition.

DIMM in slot X is an unsupported type, but valid
memory exists in another bank.

DIMM failure, all slots
in one bank (Amber)

Red

No valid or usable memory is installed in the system.

Overtemperature
(Amber)

Amber

The Health Driver has detected a cautionary temperature
level.

Red

The server has detected a hardware critical temperature
level.

Riser interlock
(Amber)

Red

The PCI riser board assembly is not seated.

Fan module (Amber)

Amber

A redundant fan has failed.

Fan module (Red)

Red

The minimum fan requirements are not being met in one or
more of the fan modules. One or more fans have failed or
are missing.

Power supply signal
interlock (Amber)

Red

The power supply signal cable is not connected to the
system board.

Internal USB connector

For more information, refer to "Internal USB functionality (on page

50

)."

Advertising
This manual is related to the following products: