Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification

21

7.1.5 Start Mated Controls

The Start_X Mated signals are TTL inputs to the drive and have 10K ohm pull-up resistors.

As per the SFF-8045 specification, the 'Start_x Mated' function is implemented as in the following table. Please refer to SFF-
8045 for a more complete definition.

Table 13: Start/Mated Controls

7.1.6 SEL_n and Enclosure Service Signals

These signals have different definitions depending on the state of -Parallel ESI and the level of enclosure service supported by
the backplane.

7.1.6.1 SEL_n and Enclosure Service Signals

-Parallel ESI is a TTL open-drain output from the drive. It is used to establish the definition of the SEL_n signals. When -Par-
allel ESI is de-asserted (high), the backplane shall preset SEL_ID information on these signals (within 1usec). When -Parallel
ESI is asserted (low), the backplane (if supported) will present enclosure service information on these signals (within 1usec).
The drive will then go through a 'discovery' phase to determine the level of enclosure services that the backplane supports (i.e.
none, SFF-8045, or SFF-8067) and behave accordingly.

7.1.6.2 SEL_ID Function

The SEL_n (TTL compatible) inputs (defined when -Parallel ESI is de-asserted) provide a binary value of loop identifier to the
drive. These 7 signals define 128 possible values and are directly translated into an 8 bit hard AL_PA via the table below. Only
AL_PA's with neutral disparity are valid values. The drive will attempt to acquire this hard AL_PA for its own during the
LIHA phase of the loop initialization process (LIP).

Table 14: SEL_ID/AL_PA

Start_2 Mated

Start_1 Mated

Spin Function

Open

Open

Drive is not mated. No spin-up will occur.

Open

Gnd

The motor will spin up with the SCSI Unit Start Cmd

Gnd

Open

The motor will spin up after a delay of 6 times the modulo 8 of
Sel_ID (in seconds)

Gnd

Gnd

The motor will spin up after drive initialization

SEL_ID

AL_PA

SEL_ID

AL_PA

SEL_ID

AL_PA

SEL_ID

AL_PA

0

EF

20

B2

40

72

60

3A

1

E8

21

B1

41

71

61

39

2

E4

22

AE

42

6E

62

36

3

E2

23

AD

43

6D

63

35

4

E1

24

AC

44

6C

64

34

5

E0

25

AB

45

6B

65

33

6

DC

26

AA

46

6A

66

32

7

DA

27

A9

47

69

67

31