0 electromagnetic compatibility – Hitachi ULTRASTAR 15K450 HUS154530VLF400 User Manual

Page 63

Advertising
background image

Hitachi Ultrastar 15K450 (FC-AL) Hard Disk Drive Specification

47

15.0 Electromagnetic Compatibility

The drive, when installed in a suitable enclosure and exercised with a random accessing routine at a maximum data rate will
comply with the worldwide EMC requirements listed below.

The drive is designed for system integration and installation into a suitable enclosure for use. As such, the drive is supplied as
a subassembly and is not subject to Subpart A of Part 15 of the FCC Rules and Regulations.

The design of the drive serves to minimize radiated emissions when installed in an enclosure that provides reasonable shield-
ing. As such, the drive is capable of meeting FCC Class A limits. However, it is the users responsibility to assure that the
drive meets the appropriate EMC requirements in their system. Shielded I/O cables may be required if the enclosure does not
provide adequate shielding, with the shields grounded to the enclosure and to the host computer.

Radiated and Conducted EMI

CISPR22

Class A

AS/NZS CISPR22

Class A

CNS13438 (Taiwan)

Class A

EN55022 (EU)

Class A

FCC Title47 Part 15 (United States)

Class A

GB9254 (China)

Class A

ICES-003, Issue 4

Class A

VCCI (Japan)

Class A

ITE Immunity

EN55024

Power Line Harmonics

EN61000-3-2 (EU)

GB17625.1 (China)

Voltage Fluctuations and Flicker

EN61000-3-3 (EU)

GB17625.2 (China)

Advertising
This manual is related to the following products: