English---17

545196750 Rev. 3 2/17/09

MAINTENANCE

WARNING:

If the idle speed can-

not be adjusted so that the cutting

attachment stops, contact your ser-

vicing dealer. Do not use the ma-

chine until it has been correctly ad-

justed or repaired.

Unit/Maintenance Safety

Disconnect the spark plug before perform-

ing maintenance, except carburetor adjust-

ments.

Muffler

CAUTION! Muffler is fitted with a catalytic

converter designed to reduce harmful ex-

haust gases.

The muffler is designed to reduce the noise

level and to direct the exhaust gases away

from the operator. The exhaust gases are

hot and can contain sparks, which may

cause fire if directed against dry and com-

bustible material.
Mufflers are equipped with a special spark

arrestor mesh. The mesh should be

checked and, if necessary. cleaned by a

servicing dealer. If the mesh is damaged,

it should be replaced. If the mesh is fre-

quently blocked, this can be a sign that the

performance of the catalytic converter is

impaired. Contact your servicing dealer to

inspect the muffler. A blocked mesh will

cause the machine to overheat and result

in damage to the cylinder and piston.

CAUTION! Never use a machine that has

a faulty or loose muffler. Ensure the muffler

bolts are tight.

Muffler bolts

WARNING:

The inside of the

muffler contain chemicals that may

be carcinogenic. Avoid contact with

these elements in the event of a

damaged muffler.

WARNING:

Mufflers fitted with

catalytic converters get very hot

during use and remain so for some

time after stopping. This also ap-

plies at idle speed. Contact can re-

sult in burns to the skin. Remember

the risk of fire!

WARNING:

Bear in mind that:

Engine exhaust fumes contain car-

bon monoxide, which can cause

carbon monoxide poisoning. For

this reason you should not start or

run the machine indoors, or any-

where that is poorly ventilated.

The exhaust fumes from the engine

are hot and may contain sparks

which can start a fire. Never start

the machine indoors or near com-

bustible material!

Spark plug

The spark plug condition is influenced by:
S

Incorrect carburetor adjustment.

S

An incorrect fuel mixture (too much or in-

correct type of oil).

S

A dirty air filter.

These factors cause deposits on the spark

plug electrodes, which may result in operat-

ing problems and starting difficulties.

If the machine is low on power, difficult to

start or runs poorly at idle speed: always

check the spark plug first before taking

any further action. If the spark plug is dirty,

clean it and check that the electrode gap is

0.024″ (0.6 mm). The spark plug should be

replaced after about a month in operation or

earlier if necessary.

CAUTION! Always use the recommended

spark plug type! Use of the wrong spark

plug can damage the piston/cylinder.

0.024″ (0.6 mm)