AC Operation

AC CIRCUIT BREAKER

VOLTAGE SELECTOR SWITCH

GFCI RESET BUTTON

A

A

C

C

C

C

I

I

R

R

C

C

U

U

I

I

T

T

P

P

R

R

O

O

T

T

E

E

C

C

T

T

O

O

R

R

S

S

1

1: Except EB3800X

Turn the voltage selector switch to either position.

With the voltage selector switch in the ‘‘120/240V’’ position, you can
use the 120V and 120/240V receptacles simultaneously. If you are
NOT using the 120/240V receptacle, but require more power from
the 120V locking plug receptacle, then select the ‘‘120V ONLY’’
position.

Plug in the appliance.

Switch ON the AC circuit breaker.

Make sure that the GFCI RESET button is pushed in (flush with its
base plate).

Start the engine (see page

).

Check GFCI operation before each use (see page 18 ).

Most motorized appliances require more than their rated power for
startup.

Do not exceed the current limit specified for any one receptacle. If an
overloaded circuit causes the AC circuit breaker or circuit protector to
switch OFF, reduce the electrical load on the circuit, wait a few minutes
and then reset the circuit breaker or circuit protector.