Choosing a location, Physical specifications, Environmental specifications – HP 2100 ER User Manual

Page 20: Choosing a location -6, Table 1-4. location criteria -6

Advertising
background image

1-6

Chapter 1

Introduction

Choosing a Location

Choosing a Location

Physical Specifications

The Fibre Bridge is designed for rackmounting. The unit can be mounted
in most standard 19-inch rack configurations. The physical
characteristics are as follows:

Table 1-3

Physical Specifications of the Fibre Bridge

Environmental Specifications

Choose a location that meets the following criteria:

Table 1-4

Location Criteria

NOTE

See Chapter 2 for rackmounting instructions.

Height

1.7 inches (4.2 cm)

Width

16.9 inches (42.9 cm)

Depth

9 inches (22.8 cm)

Physical package
weight

Approximately 8 pounds (3.6 kg)

Room temperature

40–104° F (5–40° C).

Humidity

5% to 80% relative humidity, non-condensing.

Power source

AC power voltage: 100/120V to 220/240 V.

Clearance

Rackmount configuration—requires 1 EIA
unit in a rack. 1 EIA = 1.75 inches (44 mm).

Requires 5 inches (125 mm) clearance between
the rear edge of the Fibre Bridge and the
backplane of the rack, to allow adequate room
for cables.