Choosing a location, Physical specifications, Environmental specifications – HP 2100 ER User Manual
Page 20: Choosing a location -6, Table 1-4. location criteria -6
1-6
Chapter 1
Introduction
Choosing a Location
Choosing a Location
Physical Specifications
The Fibre Bridge is designed for rackmounting. The unit can be mounted
in most standard 19-inch rack configurations. The physical
characteristics are as follows:
Table 1-3
Physical Specifications of the Fibre Bridge
Environmental Specifications
Choose a location that meets the following criteria:
Table 1-4
Location Criteria
NOTE
See Chapter 2 for rackmounting instructions.
Height
1.7 inches (4.2 cm)
Width
16.9 inches (42.9 cm)
Depth
9 inches (22.8 cm)
Physical package
weight
Approximately 8 pounds (3.6 kg)
Room temperature
40–104° F (5–40° C).
Humidity
5% to 80% relative humidity, non-condensing.
Power source
AC power voltage: 100/120V to 220/240 V.
Clearance
Rackmount configuration—requires 1 EIA
unit in a rack. 1 EIA = 1.75 inches (44 mm).