Variable speed drives/frequency converters – Husqvarna PG820 User Manual

Page 12

Advertising
background image

14

- English

The menu tree illustrated on this page outlines the
important menu options that provide useful information
for monitoring and diagnostic purposes when using the
machine.

As can be seen on the menu tree to the right, when
the machine is turned on, the variable speed drives or
frequency converters are set to display the Output Fre-
quency to the motor (a zero value will register when the
machine is in stand-by mode).

The Output Frequency page also falls under the Monitor
Menu.

It can be seen from the left hand column, the two primary
menus important to the operator are the Monitor Menu
and Fault History menu.

Navigation through the menu tree is achieved by us-
ing the up, down, left and right keys on the keypad (see
previous page).

Monitor screen

Information provided

OUTPUT FREQUENCY

Frequency motor is running at when machine is running.

REF. FREQUENCY

Frequency speed control dial is set to.

MOTOR SPEED

Speed of motor when machine is running.

MOTOR CURRENT

Current draw of motor when machine is running.

MOTOR TORQUE

Percentage of motor torque when machine is running.

MOTOR POWER

Percentage of motor power when machine is running.

MOTOR VOLTAGE

Percentage of motor voltage when machine is running.

DC LINK VOLTAGE

Indicates quality of power supply.

Parameter Menu

Motor Power

Motor Voltage

DC Link Voltage

Motor Torque

Monitor Menu

Expanded Boards

Menu

System Menu

Faults History Menu

Active Faults Menu

Keypad

Control Menu

Output Frequency

Motor Speed

Motor Current