Specifications, Applications, Prior to operation – Hitachi EC 189 User Manual

Page 9

Advertising
background image

— 9 —

English

SPECIFICATIONS

OIL TYPE CHART

2. Location

(1) In order to avoid damaging this compressor, do

not incline this compressor transversely or
longitudinally more than 10°.

CAUTION:

In order to avoid damaging the
compressor, do not allow the unit to be
tilted more than 10° when operating.

(2) Place this compressor at least 12 inches away

from obstacles that may prevent proper
ventilation. Do not place this compressor in an
area:
ⅷ where there is evidence of oil or gas leaks.

ⅷ where flammable gas vapors or materials may

be present.

ⅷ where air temperatures fall below 14°F (–10°C)

or exceed 104°F (40°C).

ⅷ where extremely dirty air or water could be

drawn into this compressor.

3. Electrical

(1) Power source:

Ensure that the power source to be utilized
conforms to the power source requirements
specified on the product nameplate.

(2) Use of an extension cord is not recommended

because it could cause the motor to overheat. It’s
preferable to use additional air hose instead of an
extension cord.

WARNING: Improper connection of the equipment-

grounding conductor can result in a risk
of shock or electrocution. Check with a
qualified electrician or service personnel if
you are in doubt as to whether the outlet
is properly grounded. Do not use any type

Model

EC189

Motor

Single-Phase, Induction Motor

Power Source

Single-Phase, 115V AC 60 Hz

Output Power

1.5 HP (1.1 KW)

Current

13.2A

Tank Capacity

8 gal. (30.3 ltr)

Maximum Pressure

125 PSI (8.6 bar)

at 40 PSI (2.8 bar)

7.2 CFM (204 ltr/min)

Free Air Delivery

at 90 PSI (6.2 bar)

6.6 CFM (187 ltr/min)

at 100 PSI (6.9 bar)

6.5 CFM (184 ltr/min)

Lubrication

Oil

APPLICATIONS

⅜ Air source of the pneumatic nailer and stapler.

WARNING: Never use compressor for applications

other than compressor for pneumatic
nailer and stapler.

PRIOR TO OPERATION

1. Initial set-up

(1) Read safety warnings before setting-up this

compressor.

(2) Ensure the oil level in this compressor pump is

adequate. If the oil level is low, replenish oil
through the filling hole so that the amount of oil
will come to a point between the maximum notch
and the minimum notch on the pump oil dipstick
according to the following OIL TYPE CHART. (Fig.
2)

Fig. 2

Minimum

Maximum

Pump oil dipstick

Ambient
temperature

Non-detergent
oil

14~32 (°F)

32~68 (°F)

68~104 (°F)

–10~0 (°C)

0~20 (°C)

20~40 (°C)

SAE 10W

SAE 20W

SAE 30