Nf-series specifications – Hellenbrand NF 1.5" User Manual

Page 2

Advertising
background image

1) The control valve and second tank adapter are solid brass

assuring you durability and long life.

2) Two self cleaning teflon coated pistons control the regenera-

tion and alternating from unit to unit with conditioned water.

They are hydraulically balanced to equalize pressure on both

sides of the piston, allowing it to shift smoothly and quietly

regardless of water pressure. Large plastic spacers and

rubber seals protect the pistons from sediment in water and

improve service flow rates.

3) The 1.5” meter allows for capacities from 625 to 53,125

gallons between regenerations and will measure flow rates

accurately between 1.5 and 75 gpm. The 1.5” low flow meter

allows for capacities from 310 to 26,350 gallons between re-

generations and will measure flow rates accurately between

0.7 and 40 gpm.

4) The NF-SERIES timer doesn’t require a time of day setting

since it adjusts automatically to meet your needs. Regenera-

tion can take place as often as every 90 minutes if needed.

5) The NF-SERIES has an adjustable cycle programmer. This

allows you to efficiently monitor all regeneration cycles in-

cluding backwash, brine and slow rinse, rapid rinse and brine

tank refill.

6) In addition to regenerating with soft water, the NF-SERIES

uses electricity only during regeneration, therefore power

outages do not affect metering. A convenient cycle position

readout dial indicates which unit is in service and the status

of the other unit. It has no complicated interlock wiring and

costs less to install.

A) Fiberglass and polyglass mineral tanks provide rust and cor-

rosion free service for years. National Sanitation Foundation

approved.

B) 1.5” high flow hub & lateral distribution system for minimal

pressure loss.

C) Hi-Capacity Cation resin has uniform and stable resin beads

assuring long life and maximum soft water.

D) Gravel underbedding assures full usage of mineral beds and

allows for a smooth and constant water flow for service and

regeneration.

E) Safety brine valve acts as a secondary shut-off in case of a

power failure during regeneration.

F) High density polyethylene brine tank has exceptional envi-

ronmental stress crack properties, eliminating cracking and

minimizing bulging.

G) Polypropylene salt grid allows insoluble materials to settle out.

CAPACITY

SERVICE

FLOW RATE BACKWASH MINERAL

BRINE

SALT SHIPPING INLET/OUTLET

MODEL

RESIN

LOW SALT

MED. SALT

HIGH SALT

FLOW RATE

PEAK

RATE

TANKS

TANK SIZE STORAGE

WEIGHT

HEIGHT

NAME

CU. FT.

GRAINS/LBS

GRAINS/LBS

GRAINS/LBS

CONT. 15 PSI

25 PSI

GPM

(INCHES)

(INCHES)

(POUNDS) (POUNDS)

(INCHES)

NF-60

2.0

38,000/12

56,000/20

64,000/30

23.0

32.0

3.5

13 x 54 18 x 40

375

404

57.5

NF-90

3.0

57,000/18

84,000/30

96,000/45

22.0

30.0

4.0

14 x 65 18 x 40

375

539

68.5

NF-120

4.0

76,000/24

112,000/40

128,000/60

25.0

34.0

5.0

16 x 65 24 x 41

525

677

68.5

NF-150-18

5.0

95,000/30

140,000/50

160,000/75

27.0

37.0

7.0

18 x 65 24 x 50

510

832

70.5

NF-150-21

5.0

95,000/30

140,000/50

160,000/75

31.0

41.0

9.0

21 x 62 24 x 50

510

946

70.5

NF-180-18

6.0

114,000/36

168,000/60

192,000/90

26.0

35.0

7.0

18 x 65 24 x 50

510

938

70.5

NF-180-21

6.0

114,000/36

168,000/60

192,000/90

30.0

40.0

9.0

21 x 62 24 x 50

510

1052

70.5

NF-210

7.0 133,000/42

196,000/70

224,000/105

29.0

39.0

9.0

21 x 62 24 x 50

510

1158

70.5

NF-240

8.0 152,000/48

224,000/80

256,000/120

32.0

42.0

12.0 24 x 72 24 x 50

340

1332

78.0

NF-270

9.0 171,000/54

252,000/90

288,000/135

31.0

41.0

12.0 24 x 72 24 x 50

340

1438

78.0

NF-300

10.0 190,000/60

280,000/100 320,000/150

30.0

40.0

12.0 24 x 72 24 x 50

340

1544

78.0

• Cubic feet of mineral and capacities as seen above are per mineral tank.

• Product improvements and design changes subject to change without notice.

• Service flow ratings are with the 1.5” meter.

• Water Pressure 30 - 100 psi.

• Limit of 2 ppm of ferrous iron. Add 3 grains of hardness per ppm of iron when sizing.

• Water temperature is not to exceed 110ºF and cannot be subject to freezing

• See owners manual for specific operating details

conditions.

• These conditioners will not purify or make your water safe to drink.

• Refer to Hellenbrand Bulletin 2050 “Flow Rates and Soft Water Quality (Hardness

• Inlet/outlet heights are approximate only.

Leakage) if your application requires that levels of hardness leakage do not exceed “x”.

Manufactured by:

HELLENBRAND, INC.

(800) 626-1417

www.hellenbrand.com

106610

1/05-500

1/21/09-LBRY

DEALER NAME:

Meter Information:

Meter Accuracy Range 1-1/2” (Standard) 1.5 - 75 gpm ± 5%

1-1/2” (Low Flow) 0.7- 40 gpm ± 5%

Meter Capacity Range 1-1/2” (Standard) Standard: 625-10,625 gals.

Extended: 3,125 - 53,125 gals.

1-1/2” (Low Flow) Standard: 310 - 5,270 gals.

Extended: 1,550 - 26,350 gals.

NF-SERIES Specifications

A

B

C

D

G

F

E

Advertising