Holmes HM1280 User Manual

Page 2

Advertising
background image

19. Do not use humidifier in an area where humidity level

is in excess of 50%. Use a hygrometer, available at

your local retailer or through the manufacturer, to

measure the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

serviceable parts. All servicing should be performed by

qualified personnel only.

21. Never place housing under water flow or immerse in

liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the water

tank.

24. To prevent damage to surfaces, do not place humidifier

under overhanging surfaces.

25. NEVER operate unit without water in the tank.

26. Do not move unit after it has been used until unit cools

completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT

SAFETY INSTRUCTIONS

Consumer Safety Information

NOTE: This is an electrical appliance and requires attention

when in use.

NOTE: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has plenty

of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions

The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping over

a longer cord. If a longer cord is necessary an approved

extension cord may be used. The electrical rating of the

extension cord must be equal to or greater than the rating

of the humidifier. Care must be taken to arrange the

extension cord so that it will not drape over the countertop

or tabletop where it can be pulled on by children or

accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes

®

Cool Mist humidifier draws dry air through the

rear air intake grill area. This air is then passed through a

moisture–laden wick filter, which retains the minerals and

deposits in the water. The resulting moist air is directed back

into the room from the top air grill.
NOTE: This humidification system provides a cool, invisible

moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is between

40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is disconnected from the

electrical outlet and the switch is in the OFF position.

2. Select a location for your humidifier, on a flat surface,

about 4" away from the wall. Do not place your

humidifier on furniture; a floor location that will not be

damaged by moisture is best.

3. Remove the water tank by holding the tank handle and

lifting straight upward (see figure 2).

4. Remove the main housing by lifting straight upward.

Check to see that the wick filter is properly in place.

Replace the humidifier housing.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

C L E A N I N G / M A I N T E N A N C E

S T O R A G E I N S T R U C T I O N S

When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire, electric

shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.

2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your

humidifier on an inside wall near an electrical outlet.

The humidifier should be at least 4” away from the

wall for best results.

5. NEVER place humidifier in an area where it is accessible

to children. NEVER use humidifier in a closed room,

particularly where a child may be sleeping, resting, or

playing (a closed room may result in excessive

humidity).

6. WARNING: Do not attempt to refill humidifier without

first unplugging the unit from its electrical outlet.

Failure to heed this warning may cause personal injury.

Be sure to unplug the unit by pulling on the plug and

not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings.

9. DO NOT operate any appliance with a damaged cord or

plug, after the appliance malfunctions, or if it has been

dropped or damaged in any manner. Return appliance

to manufacturer for examination, electrical or

mechanical adjustment, or repair.

10. Use appliance only for intended household use as described

in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to

persons. The use of attachments not recommended or sold

by the manufacturer may cause hazards.

11. DO NOT use outdoors.

12. Always place humidifier on a firm, flat, level surface. A

waterproof mat or pad is recommended for use under

the humidifier. NEVER place it on a rug or carpet, or on

a finished floor that may be damaged by exposure to

water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the

wall. Moisture could cause damage, particularly to wall

paper.

14. Humidifier should be unplugged when not in use.

15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly maintenance

to operate appropriately. Refer to daily and weekly

cleaning procedures. Use only cleaners and additives

recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner, furniture

polish, paint thinner, or other household solvents to

clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

new filter will register in the blue section reading GOOD filter.

After frequent use of your humidifier, the FilterCheck

®

indicator will let you know when the filter should be changed.

When the needle is in the red CHANGE section this means the

proper amount of moisture is not getting into your air due to

the large amount of minerals and sediment that have become

trapped in your filter. At this point you should replace your

filter. It is important to change your filter to get the best

performance from your humidifier.

To replace the filter, follow the below steps.

1. Turn the power switch off and unplug the humidifier

from the electrical outlet.

2. Remove the tank and main housing to access the base

tray.

3. Discard the old filter and follow weekly cleaning

instructions.

4. Insert a new filter into the filter support in the base.

5. Replace the main housing and then the tank.

6. Repeat Operating Instruction steps.

It will take about 30 minutes for the humidifier to reach

maximum output.
You can obtain a new filter by calling 1-800-5-HOLMES in the

USA or by visiting your nearest retailer or authorized service

center. This humidifier takes model HWF62 replacement filter.

STORAGE INSTRUCTIONS

If your humidifier will not be in use for two days or more, or

at the end of the season follow these instructions.
1. Clean and dry the humidifier thoroughly as per the

Weekly Maintenance instructions.

2. Let the humidifier dry completely before storing. Do

not store with water inside the base.

3. Do not store with the reservoir cap in place.

4. Throw away the wicking filter. Do not store with wick

filter in place

5. Store in a cool dry location.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry indoor

air. To get the most of the benefit from the humidifier and

avoid product failure, follow all maintenance instructions

carefully. If the recommended care and maintenance guidelines

are not followed, micro-organisms may be able to grow in the

water within the humidifier.

Daily Maintenance

1. Before cleaning, set the control switch to OFF position

and unplug the unit from the electrical outlet.

2. Lift off the tank and the housing of the humidifier.

3. Carry the base and the tank to the sink, remove the wick

filter, then drain and rinse the base and tank thoroughly to

remove any sediment and dirt. Wipe clean and dry with a

clean soft cloth or paper towel. (DO NOT use metal cleaning

utensils or abrasive cleaners)

4. Put the filter back in the filter supports, replace the

housing, then refill the tank with cool tap water as

instructed in filling the water tank instructions.

Weekly Maintenance

Remove scale:
1. Repeat steps 1-3 above.

2. Clean the base by partially filling the base with one

8-oz cup of undiluted white vinegar, or by using

CleanseClean

®

. Let solution stand 20 minutes, clean

all interior surfaces with a soft brush.

3. Dampen a cloth with undiluted white vinegar and wipe

out entire base to remove scale.

4. Rinse with clean warm water to remove scale and the white

vinegar solution before beginning to disinfect the tank.

Disinfect tank:
1. Fill tank with

1

/

2

teaspoon of chlorine bleach and

1

/

2

gallon of water.

2. Let the solution stand for 20 minutes, swishing every

few minutes. Wet all surfaces.

3. Empty the tank after 20 minutes, and rinse well with

water until the bleach smell is gone. Dry with a clean

cloth or paper towel.

4. Refill the water tank with cool water; replace the housing

and the water tank. Repeat ALL Operating Instructions.

THIS PRODUCT IS EQUIPPED WITH A POLARIZED PLUG (a plug having one blade wider than

the other). This plug will fit into the power outlet only one way. If the plug does not fit fully

into the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install

the proper outlet.

DO NOT DEFEAT THE SAFETY PURPOSE OF THIS

POLARIZED PLUG IN ANY WAY

FILLING THE WATER TANK

NOTE: This humidifier holds about 1 gallon of water in the

tank and humidifier base. The humidifier will produce up to

2.5 gallons of moisture over a 24-Hour period, depending on

the room humidity and temperature.
1. Be sure the humidifier is disconnected from the

electrical outlet.

2. Remove the tank from the base by holding the handle

and lifting straight up (see figure 2).

3. Twist off the tank cap located on the bottom of the tank

by turning counter clockwise and fill the water tank

with cool, fresh water.
Do not fill with warm water as this may cause

leaking.

4. After filling the tank, replace the tank cap by firmly

turning clockwise and then replace the water tank on

the base. The tank will immediately begin to empty

into the base.

5. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

1. Turn the Power knob to the desired setting (LO or HI).

2. When the desired humidity level is reached the speed

control can be set to the LO setting to reduce the

humidification rate.

NOTE: Allow up to 30 minutes for the filter to fully absorb

water and the unit to produce the maximum moisture output.
3. When the water tank is empty and the water in the

base is almost empty, you need to refill the tank. The

fan will continue to run to help dry the humidifier.

Switch off and unplug the unit. Please follow the Daily

Cleaning instructions before refilling the water tank.

4. Refill the tank as directed in the Pre-Operating

Instructions.

If you do not plan to use the humidifier for two or more

days, make sure any residual water is drained from the

water tank, base and wick filter to prevent algae or bacteria

growth.

REPLACING THE FILTER

Through normal use, waterborne minerals and sediment

become trapped in the wick filter. The harder your water, the

greater the amount of minerals in the water, and the more

often you will need to change your filter. In general, a

brown filter indicates a need to replace the filter.
You will be able monitor the condition of the filter in your

humidifier by checking the FilterCheck

®

Indicator. When the

unit is off or empty of water

the FilterCheck

®

will read in

the OFF/FILL position. Within

60 minutes of use the

FilterCheck

®

will move from

the OFF position and indicate

your filter condition. A brand

F E AT U R E S - O P E R AT I O N S

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

A. Circular Filter

Supports

B. Circular

Extended Life

Filter

C. Humidifier Base

B

A

C

Figure. 1

A. Humidifier Tank

B. Carry Handle

C. Humidifier

Housing

D. 2-Speed

Humidity

Control/Power

Knob

E. Humidifier Base

F. FilterCheck

®

Indicator

A

B

C

D

E

F

Figure. 2

Figure 3

HM128006EM1.qxd 8/22/06 16:04 Page 2

Advertising