Installation, Typical installation – Hitachi 308996J User Manual

Page 7

Advertising
background image

308996

7

Installation

Fig. 2

KEY

A

Pump

B

Wall Bracket

D

Gun Air Hose

E

Bleed-Type Master Air Valve
(required, for pump)

F

Pump Air Regulator

H

Electrically Conductive Air Supply Hose

G

Air Relief Valve (Falcon II packages only)
(shown in exploded view)

J

Air Line Filter

K

Bleed-Type Master Air Valve
(for accessories)

L

Pump Outlet

M

Wet Cup

N

Electrically Conductive
Fluid Supply Hose

R

Gun Swivel

S

Air–Assisted Spray Gun

T

Suction Hose

U

Strainer

Y

Ground Wire and Clamp
(required; see page 5
for installation instructions)

W Air Line Drain Valve
Z

Gun Air Regulator

TYPICAL INSTALLATION

1

Do not stretch hose tight; let it hang as shown, to
assist fluid flow into the pump. Adjust suction tube
so it’s about a 1/2 inch off bottom of the pail.

B

S

R

Y

W

H

J

K

G

A

U

T

Z

E

F

1

D

D

N

9140B

N

L

M

Main Air Line

(G) Air Relief Valve

F

E

G

Advertising