Pressure control replacement, Warning, Caution – Hitachi GM7000 231327 User Manual

Page 26

Advertising
background image

308398

26

Pressure Control Replacement

WARNING

INJECTION HAZARD
To reduce the risk of serious injury,
whenever you are instructed to relieve
pressure, follow the Pressure Relief
Procedure
on page 10.

1.

Relieve pressure.

2.

Disconnect both hoses at the pressure control
while holding the fitting or elbow (A) firmly. See the
CAUTION, below. Note the original location of
each hose to be sure you reassemble them cor-
rectly at the end of this procedure. See Fig. 21.

CAUTION

Do not allow the elbow (A) to turn when removing or
connecting the hoses. Turning the fitting or elbow
can shift the calibration of the pressure control.

3.

Remove the four mounting screws and washers
(302, 303, 304) from the pressure control cover
(76). See Fig. 22.

4.

Carefully remove the pressure control cover (76)
so as not to stress the cables.

5.

Disconnect the black and white wires of the pres-
sure control cable (314) from the pressure control
cover.

6.

Disconnect the potentiometer cable assembly
(310) from the pressure control cover.

7.

Disconnect the red power lead (B) from the ON/
OFF switch.

8.

Loosen the ground terminal screw (317) and
disconnect the ground lead (C).

9.

Pull off the pressure control cover.

Fig. 21

63

76

TO
FIL-
TER

A

A

1

To the pump.

1

2

To the filter.

2

06873

06872A

Fig. 22

304

B

C

302

304

303

317

310

314

76

WARNING

Do not attempt to adjust or calibrate the pressure
control. If the pressure control is faulty, replace it.

10. Reassemble in the reverse order; attach ground

wire (C), power lead (B), and the black and white
connectors. Attach the pressure control cover (76)
using the four mounting screws and washers (302,
303, 304).

Advertising