Capacities and raid architecture – Hitachi 9900 Series User Manual

Page 32

Advertising
background image

23

Capacities and RAID
Architecture

Storage Capacity of the Lightning 9900

Series

The Lightning 9900

Series supports an unmatched range of capacities as shown

in Table 3.

System Capacities and Number of disk drives for various configurations

Raw System

Raw capacity with

Raw capacity with

Raw capacity with

Configuration

18GB drives

73GB drives

180GB drives

Lightning 9960
One Array Frame

1.7TBs = 96 disks

7.0TB = 96 disks

16.6TB = 96 disks

Lightning 9960
Six Array Frames

9.4TB = 512 disks

37.4TB = 512 disks

88.3TB = 512 disks

Lightning 9910

.9TB = 48 disks

3.5TB = 48 disks

8.3TB = 48 disks

Advantages of the Lightning 9900

Series RAID Hardware

Hitachi designs the most advanced RAID (Redundant Array of Independent Disks)

controllers in enterprise storage to interface to its disk subsystems. These intelligent
controllers provide disk interface and RAID management, offloading these tasks to
dedicated processors. Each Lightning 9900

Series ACP controller supports RAID-1+

and RAID-5 (parity RAID). All disks in the system are defined as part of a RAID array
of one type or another. Non-volatile RAM on each controller accelerates RAID functions,
particularly disk writes.

RAID-1+

With the announcement of the Lightning 9900 Series RAID-1+ was introduced.

RAID-1+ is a 2 Data + 2 Data disk arrangement (four disks total) in a RAID-1+0
configuration with a twist – a rotating copy.

RAID-5 – Distributed Parity

RAID-5 arrays consist of four disks. Data is striped across RAID-5 arrays in a fashion

similar to RAID-1+, but RAID-5 provides fault resilience by keeping parity information on
each stripe of data. If a failure occurs, the contents of that block can be recreated by reading
back the other blocks in the stripe along with the parity. Parity information is distributed
throughout the array to minimize potential bottlenecks in the event of a need to rebuild
data from a failed disk. The overhead of RAID-5 is equivalent to one disk drive, regardless
of the size of the array.

RAID Rebuild Capability

In the event of a disk failure, RAID-1+ or RAID-5 arrays can be rapidly and

automatically rebuilt using available “hot-spare” drives. The Lightning 9900

also allows

logical volumes to be expanded online. Configurations for RAID-1+ and RAID-5 are
shown in Figure 20.