Caution, B. wiring diagram – Heat & Glo Fireplace Heat & Glo Electric Stove TiaraE 4035-822 User Manual

Page 13

Advertising
background image

Heat & Glo • TiaraE• 4035-822 Rev F • 01/05

13

B. Wiring Diagram

BLK

BLK

WHT

BLK

BLU

PLUG

HEATER SYSTEM

CAUTION!

Risk of electrical shock!

Disconnect electric power

before servicing.

!

If any of the original wire as
supplied with the appliance must
be replaced, it must be replaced
with an equivalent wire gauge
and 105 degree rated wire.

M

FAN

THERMOSTAT

HEATER

SWITCH

BLK

BLK

MAIN

POWER

M

BLK

BLK

WHT

L

WHT

ORG

WHT

BLK

BLK

BLK

BLK

DIMMER

SWITCH

L

BLK

WHT

BLK

BLK

WHT

ORG

All wiring is to be done by a
qualified electrician.

Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and dangerous
operation. Verify proper operation after servicing.

CAUTION

Advertising