REPLACING THE FILTERS

Through normal use, waterborne minerals and sediment

become trapped in the wick filter. The harder your water,

the greater the amount of minerals in the water, and the

more often you will need to change your filter.
You will be able to monitor the life of the filter in your

humidifier by checking the FilterCheck

®

Indicator. After 60

minutes of use, FilterCheck

®

Indicator will move and indicate

your filter condition. A brand new filter will register in the

section reading GOOD filter. After frequent use of your

humidifier, the FilterCheck

®

Indicator will let you know when

the filters need to be changed, see Figure 2.
When the needle is in the CHANGE section, this means the

proper amount of moisture is not getting into your air due

to the excessive minerals and sediment that have become

trapped on your filters. At this point, you should replace

your filter. It is important to change your filter as indicated

to obtain stated performance level.
To replace the filter, follow the steps below:
1. Turn the unit off and disconnect from the electrical outlet.

2. Remove the tank from the housing.

3. Unlock the housing from the base by turning the lock

knob to the unlocked position.

4. Lift the housing straight up and place to the side.

5. Unlock the wick holder from the base by turning the

lock knob to the unlocked position.

6. Remove the wicks from the wick holder.

7. Follow the weekly cleaning instructions.

8. Insert new filters into the wick holder and lock the

wick holder back onto the base.

9. Replace the housing onto the base and lock it into place.

10. Fill the tank and place back into housing.

11. Repeat Operating Instructions.

It will take about 30 minutes for the humidifier to reach

maximum output.
You can purchase replacement filters (model HWF100-

UC2/HWF100 – 2 filters) at your local retailer, by calling 1-

800-546-5637, filling out the accessory card, or by visiting

www.holmesproducts.com. It is recommended that a

replacement filter is purchased for uninterrupted use.

CLEANING AND MAINTENANCE INSTRUCTIONS

Humidifiers provide comfort by adding moisture to dry,

heated indoor air. To benefit most from the humidifier and

avoid product misuse, follow all instructions carefully.

Please note that this is an electrical appliance and requires

attention when in use.
In addition, if you do not follow the recommended care and

maintenance guidelines, micro-organisms may be able to grow

in the water within the water tank. You must routinely follow

the cleaning procedures that follow in order to ensure proper,

efficient operation of your humidifier. Proper maintenance and

cleaning is essential to the continued performance of your unit

and the avoidance of algae or bacteria build-up.

DAILY MAINTENANCE
1. Be sure the unit is OFF and is disconnected from the

electrical outlet.

2. Remove the housing and the tank from the humidifier

and place in sink or tub.

3. Carry the base of the unit to the sink, remove the

wick, place in sink, drain any remaining water and

rinse thoroughly to remove any sediment or dirt. Wipe

clean, and dry with a clean cloth or paper towel.

4. Drain the water from the tank into the sink and rinse

tank thoroughly. Wipe clean, and dry with a clean

cloth or paper towel.

5. Put filters back into wick holder making sure the rivet

attaches to the holder. Lock the wick holder back into

place. Replace the housing and lock it into place.

Refill the tank with cool tap water as instruction earlier

in the filling instructiosn. Do Not overfill.

6. Follow Operating Instructions.

NOTE: The Tray is dishwasher safe (TOP RACK ONLY)

for easy cleaning.

WEEKLY MAINTENANCE
To Remove Scale:

1. Repeat steps 1-4 above.

2. Clean the base by partially filling the base with one

8-oz cups of undiluted white vinegar, or by using

Cleanse Clean™ (Model S1710) by the manufacturer.

Leave this solution in the base for 20 minutes, while

cleaning the all interior surfaces with a soft brush.

Remove base scale by wiping the base with a cloth

dampened with undiluted white vinegar.

3. Rinse with clean warm water to remove the cleaning

solution before disinfecting the tank.

serviceable parts. All servicing should be performed

by qualified personnel only.

21. Never place housing under water flow or immerse in liquids.

22. Do not plug in the cord with wet hands: electric shock

could result.

23. Do not pour water in any openings other than the

water tank.

24. To prevent damage to surfaces, do not place humidifier

under overhanging surfaces.

25. NEVER operate unit without water in the tank.

26. Do not move unit after it has been used until unit cools

completely.

27. Use both hands when carrying full tank of water.

PLEASE READ AND SAVE

THESE IMPORTANT SAFETY

INSTRUCTIONS

Consumer Safety Information
NOTE:
This is an electrical appliance and requires

attention when in use.
NOTE: If moisture forms on the walls or windows of the

room, turn off the humidifier. The room already has plenty

of humidity and additional moisture may cause damage.
NOTE: DO NOT block air inlet or outlet.

Cord and Plug Installation Safety Instructions
The length of cord used on this appliance was selected to

reduce the hazards of becoming tangled in, or tripping

over a longer cord. If a longer cord is necessary an

approved extension cord may be used. The electrical rating

of the extension cord must be equal to or greater than the

rating of the humidifier. Care must be taken to arrange the

extension cord so that it will not drape over the countertop

or tabletop where it can be pulled on by children or

accidentally tripped over.

HOW COOL MIST WORKS

Your Holmes

®

Cool Mist humidifier draws dry air through

the rear air intake grill area. This air is then passed

through a moisture–laden wick filter, which retains the

minerals and deposits in the water. The resulting moist air

is directed back into the room from the top air grill.
NOTE: This humidification system provides a cool,

invisible moisture output. It is normal not to see the mist.
NOTE: A humidity level below 20% can be unhealthy and

uncomfortable. The recommended humidity level is

between 40%-50%.

PRE-OPERATING INSTRUCTIONS

1. Be sure the humidifier is switched to OFF and the unit

is disconnected from the electrical outlet.

2. Select a location for your humidifier, on a flat surface,

about 4” away from the wall. DO NOT place the

humidifier on a finished floor or near furniture, which

can be damaged by moisture or water. Place on a

moisture-resistant surface.

FILLING THE WATER TANK

1. Remove the tank from the housing of the humidifier by

grabbing the handle of the tank and pulling forward. Lift

the tank out of the housing and bring to the faucet. Turn

the tank upside down and twist off the tank cap by turning

counter clockwise. Fill tank with cool, fresh tap water. DO

NOT fill with warm water as this may cause leaking.

Replace the cap on tank FIRMLY.

2. When full, carry the tank to the humidifier and place

it into the housing. There is a locating tab located on

the tank base for easy guidance. The tank holds 1.3

gallons of water. The tank will immediately begin to

empty into the base.

3. Plug the power cord into a 120V AC electrical outlet.

OPERATING INSTRUCTIONS

Your humidifier is equipped with a technologically advanced

AccuSet Plus™ Digital Humidistat. You can set the humidifier to

run continuously in manual mode or set the AccuSet Plus™

Digital Humidistat to your desired humidity setting. The AccuSet

Plus™ Digital Humidistat will automatically turn the humidifier

ON or OFF, depending on the preset comfort level. The comfort

level ranges between 35% and 65% relative humidity.
Manual Mode Instructions:
1. Plug the humidifier into a 120V AC electrical outlet.

2. The display will show the current room humidity.

P L E A S E R E A D A N D S AV E T H E S E

I M P O R TA N T S A F E T Y I N S T R U C T I O N S

F E AT U R E S - O P E R AT I O N S

F E AT U R E S - O P E R AT I O N S

Thank you for purchasing this Holmes

®

product. We

understand the value of quality and are committed to

making superior products that stand the test of time. We

trust this product will exceed your expectations of quality

and reliability. We hope that you enjoy this product and

will consider purchasing another Holmes

®

product in the

future. To see our full product line or if you have any

questions or comments about this product, please visit our

website at: www.holmesproducts.com.
When using electrical appliances, basic safety precautions

should always be followed to reduce the risk of fire, electric

shock, and injury to persons, including the following:
1. Read all instructions before using the appliance.

2. To avoid fire or shock hazard, plug the appliance

directly into a 120V AC electrical outlet.

3. Keep the cord out of heavy traffic areas. To avoid fire

hazard, NEVER put the cord under rugs or near heat

registers.

4. DO NOT place humidifier near heat sources such as

stoves, radiators, and heaters. DO locate your humidifier

on an inside wall near an electrical outlet. The humidifier

should be at least 4” away from the wall for best results.

5. NEVER place humidifier in an area where it is accessible

to children. NEVER use humidifier in a closed room,

particularly where a child may be sleeping, resting, or

playing (a closed room may result in excessive humidity).

6. WARNING: Do not attempt to refill humidifier without

first unplugging the unit from its electrical outlet. Failure

to heed this warning may cause personal injury. Be sure

to unplug the unit by pulling on the plug and not the cord.

7. Never place anything over moisture outlet when the

unit is running.

8. NEVER drop or insert any object into any openings.

9. DO NOT operate any appliance with a damaged cord

or plug, after the appliance malfunctions, or if it has

been dropped or damaged in any manner. Return

appliance to manufacturer for examination, electrical

or mechanical adjustment, or repair.

10. Use appliance only for intended household use as described

in this manual. Any other use not recommended by the

manufacturer may cause fire, electric shock, or injury to

persons. The use of attachments not recommended or sold

by the manufacturer may cause hazards.

11. DO NOT use outdoors.

12. Always place humidifier on a firm, flat, level surface.

A waterproof mat or pad is recommended for use

under the humidifier. NEVER place it on a rug or

carpet, or on a finished floor that may be damaged by

exposure to water or moisture.

13. DO NOT allow the Moisture Outlet to directly face the wall.

Moisture could cause damage, particularly to wall paper.

14. Humidifier should be unplugged when not in use.

15. NEVER tilt, move, or attempt to empty unit while it is

operating. Shut off and unplug before removing the

water tank and moving the unit.

16. This humidifier requires daily and weekly maintenance to

operate appropriately. Refer to daily and weekly

cleaning procedures. Use only cleaners and additives

recommended by the manufacturer.

17. NEVER use detergents, gasoline, glass cleaner,

furniture polish, paint thinner, or other household

solvents to clean any part of the humidifier.

18. Excessive humidity in a room can cause water

condensation on windows and some furniture. If this

happens, turn the humidifier OFF.

19. Do not use humidifier in an area where humidity level

is in excess of 50%. Use a hygrometer, available at

your local retailer or through the manufacturer, to

measure the humidity.

20. DO NOT attempt to repair or adjust any electrical or

mechanical functions on this unit. Doing so will void

your warranty. The inside of the unit contains no user

3. To start the unit, push the button once for the

HIGH (3) manual setting.

4. Press the button again for the MEDIUM (2) manual setting

and again for LOW (1). After the selection is made, the

display will return to show the current room humidity.

5. To stop the unit, press and hold the button for two seconds,

or keep pressing the button until the display reads OFF (OF).

AccuSet Plus™ HUMIDISTAT INSTRUCTIONS
To take advantage of the AccuSet Plus™ Digital Humidistat,

press the

button until the speed is set in either the AUTO

HIGH (A3), AUTO MEDIUM (A2) or AUTO LOW (A1) setting.

Then adjust the set humidity by using the up and down

buttons. Humidity will increase or decrease in increments of

5%. When the humidity level is set, the display will return to

show the current room humidity. When the room humidity

level rises above the set humidity, the humidifier will stop.

When the humidity level drops below the set humidity, the

humidifier will turn on automatically.
NOTE: Allow up to 30 minutes for the filter to fully absorb

water and for the unit to produce moisture.
NOTE: The AccuSet Plus™ Humidifier has memory. This

means that when you turn the unit back on, it will be at

the last setting the humidifier was set at.
If you do not plan to use the humidifier for two or more days,

make sure any residual water is drained from the water tank,

base and wick filter to prevent algae or bacteria growth.
Extended Run Time Setting:
By setting your humidifier to a specific humidity level, you

are actually also extending the run time. Since the unit will

turn on and off to maintain the set humidity level, less

water will be used, so you will need to fill the unit less than

you would on manual setting.

USING THE PROGRAMMABLE TIMER
AccuSet Plus™ allows the user to program the humidifier to

come on at a preset time, or turn off after a set amount of time.
Setting the Off Timer:
1. Set the mode and/or humidity you wish the humidifier

to run in.

2. While the humidifier is running, press and hold the up

and down buttons simultaneously for 2 seconds.

The display will flash “00”.

3. By pressing the up and down buttons, program the

humidifier to turn off up to 16 hours later in increments

of 1 hour.

4. After setting the timer, the display will return to show the

current room humidity. The timer light will illuminate to

show that the timer is activated.

5. After the predetermined length of time has passed, the

humidifier will automatically shut off.

Setting the On Timer:
1. While the humidifier is off, press and hold the up and

down buttons simultaneously for 2 seconds.

2. By pressing the up and down buttons, program the

humidifier to turn on up to 16 hours in advance in

increments of 1 hour.

3. After the preset length of time has passed, the

humidifier will automatically turn on Auto Mode HI

speed at 45% for a preset time of 2 hours.

AccuSet Plus

TM

Remote Instructions (For HM630RC

only)
1. Insert 2 AAA batteries into back of remote control.

2. Press the MODE/OFF button on remote to begin

operation.

3. Use the remote to control the same features as the

base unit.

NOTE: The timer function can only be activated on the

base unit. It cannot be activated via the remote control.
NOTE: Do not mix new

and old batteries. Do not

mix alkaline, standard

(carbon-zine), or

rechargeable (nickel-

cadmium) batteries.

R E P L A C I N G / C L E A N I N G

C L E A N I N G A N D M A I N T E N A N C E

THIS APPLIANCE HAS A POLARIZED PLUG (one blade is wider than the

other). To reduce the risk of electric shock, this plug is intended to fit in

a polarized outlet only one way. If the plug does not fit fully in the

outlet, reverse the plug. If it still does not fit, contact a qualified

electrician to install the proper outlet.

DO NOT ATTEMPT TO MODIFY THIS PLUG OR DEFEAT THIS

SAFETY FEATURE IN ANY WAY.

Figure 2

Figure 1

A. Tank

B. Tank Handle

C. Base

D. Humidifier Housing

E. Control Panel

F. FilterCheck

®

D

B

A

E

F

C

HM630/630RC07EM1.qxd:HM495UC07EFM1.qxd 4/12/07 8:56 PM Page 2

Advertising