The basic installation of this Smoke Alarm is similar whether you want to
install one Smoke Alarm, or interconnect more than one Smoke Alarm.
If you are interconnecting more than one Smoke Alarm, you MUST read
“Special Requirements For Interconnected Smoke Alarms” below before
you begin installation.

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you
will install this unit at the circuit breaker or fuse box before beginning
installation. Failure to turn off the power before installation may result
in serious electrical shock, injury or death.

1. Remove the mounting bracket from

the base, and attach it to the junction
box.

2. Using wire nuts, connect the power

connector to the household wiring.

3. Plug the power connector into the back of the Smoke Alarm.

4. Position the base of the Smoke Alarm over the mounting bracket and

turn. The Alarm can be positioned over the bracket every 90°. Turn the
Smoke Alarm clockwise (right) until the unit is in place.

5. Check all connections.

Improper wiring of the power connector or the wiring leading to the
power connector will cause damage to the Alarm and may lead to a
non-functioning Alarm.

Continued above...

ELECTRICAL SHOCK HAZARD. Do not restore power until all Smoke
Alarms are completely installed. Restoring power before installation is
complete may result in serious electrical shock, injury or death.
6. Make sure the Smoke Alarm is receiving AC power. Under normal

operation, the Green power indicator light will shine continuously.

7. If the Green power indicator light does not light, TURN OFF POWER

TO THE JUNCTION BOX and recheck all connections. If all connections
are correct and the Green power indicator still does not light when you
restore the power, the unit should be replaced immediately.

8. Test each Smoke Alarm. Press and hold the Test/Silence button until the

unit alarms. When testing a series of interconnected units you must
test each unit individually. Make sure all units alarm when each one
is tested.

If any unit in the series does not alarm, TURN OFF POWER and recheck
connections. If it does not alarm when you restore power, replace it
immediately.

Special Requirements For Interconnected Smoke Alarms

• Failure to meet any of the above requirements could damage the

units and cause them to malfunction, removing your protection.

• AC and AC/DC Smoke Alarms can be interconnected. Under AC

power, all units will alarm when one senses smoke. When power is
interrupted, only the AC/DC units in the series will continue to send
and receive signals. AC powered Smoke Alarms will not operate.

Interconnected units can provide earlier warning of fire than stand-alone
units, especially if a fire starts in a remote area of the dwelling. If any unit
in the series senses smoke, all units will alarm. To determine which Smoke
Alarm initiated an alarm, see table:

On Initiating Alarms

Red LED flashes rapidly

On All Other Alarms

Red LED is Off

Interconnect units within a single family residence only. Otherwise all house-
holds will experience unwanted alarms when you test any unit in the series.
Interconnected units will only work if they are wired to compatible units and
all requirements are met. This unit is designed to be compatible with:
First Alert

®

Smoke Alarm Models SA4120, SA4121B, SA100B, 9120 series

and BRK Electronics

®

Smoke Alarm Models 100S, 4120 series, 9120 series,

7010 series; BRK Electronics

®

Heat Alarm Models HD6135F, HD6135FB;

Smoke/CO Alarm Models SC6120B, SC9120B; CO Alarm Model CO5120B;
Relay Modules RM3 and RM4.

Interconnected units must meet ALL of the following requirements:

• A maximum of 18 compatible units may be interconnected

(Maximum of 12 Smoke Alarms).

• The same fuse or circuit breaker must power all interconnected units.

• The total length of wire interconnecting the units should be less than

1000 feet (300 meters). This type of wire is commonly available at
Hardware and Electrical Supply stores.

• All wiring must conform to all local electrical codes and NFPA 70 (NEC).

Refer to NFPA 72, NFPA 101, and/or your local building code for
further connection requirements.

FOLLOW THESE INSTALLATION STEPS

INSTALLATION STEPS, Continued

STAND-ALONE ALARM ONLY:

Connect the white wire on the power connector to the neutral wire in
the junction box.

Connect the black wire on the power connector to the hot wire in the
junction box.

Tuck the orange wire inside the junction box. It is used for interconnect
only.

INTERCONNECTED UNITS ONLY:
Strip off about 1/2” (12 mm) of the plastic coating on the orange wire
on the power connector.

Connect the white wire on the power connector to the neutral wire in
the junction box.

Connect the black wire on the power connector to the hot wire in the
junction box.

Connect the orange wire on the power connector to the interconnect
wire in the junction box. Repeat for each unit you are interconnecting.
Never connect the hot or neutral wires in the junction box to the orange
interconnect wire. Never cross hot and neutral wires between Alarms.

STAND-ALONE ALARM ONLY:

If you are only installing one Smoke Alarm, restore power to the
junction box.

INTERCONNECTED UNITS ONLY:

If you are interconnecting multiple Smoke Alarms, repeat steps
1-5 for each Smoke Alarm in the series. When you are finished,
restore power to the junction box.

#

}

)

}

*

&

%

$

!





!

"

"

#

A. Unswitched 120VAC

60 Hz source

B. To additional units; Maximum = 18 total

(Maximum 12 Smoke Alarms)

1. Smoke Alarm

2. Ceiling or Wall

3. Power Connector

4. Wire Nut

5. Junction Box

6. Neutral Wire (Wht)

7. Interconnect Wire

(Orange)

8. Hot Wire (Blk)

QUICK INSTALLATION INSTRUCTIONS

Easily expand an existing interconnected 120V AC hardwired system by
simply replacing one Alarm in the series with the First Alert

®

ONELINK

®

Model SA520. Then add additional battery-operated Alarms to expand the
system with no additional electrical work.

1. Insert the batteries into the battery

drawer of the first Alarm and close
the drawer.

2. The Alarm will sound with a chirp.

3. If you purchased the Talking Smoke

and Carbon Monoxide Alarm, you
will now be prompted to set the
Alarm's location. Follow the direction given by the Alarm.

NOTE: Steps 4 through 6 need to be completed within two minutes.
If more than two minutes pass, the Green power LED will stop
blinking. Simply open the battery drawer of the second Alarm
and repeat steps 4 through 6.

4. Insert the batteries into the battery drawer of the next Alarm. DO NOT

CLOSE THE DRAWER.

5. Press and hold the test button and then close the battery drawer.

6. Once you hear the unit chirp, release the test button. The Green power

LED will start to blink indicating the ONELINK

®

Alarm is waiting for

program data from one of the other setup ONELINK

®

Alarms.

7. Press and hold the test button on the first Alarm, until the second Alarm

chirps and its Green power LED stops blinking. Then release the test
button.

8. If you purchased the Talking Smoke and Carbon Monoxide Alarm, you

will now be prompted to set the Alarm's location. Follow the directions
given by the Alarm.

9. If you have purchased the hardwired battery back-up ONELINK

®

Alarm,

you can now connect the hardwired Alarm by installing the three-wire
connector on the ceiling to the Alarm.

10. Repeat steps 4-9 for additional ONELINK

®

Alarms.

You have now successfully linked your new ONELINK

®

Alarms.

To add additional Alarms at a later time, follow steps 4 through 9.