Frymaster FOOTPRINT 8196345 User Manual

Page 10

Advertising
background image

1-4

FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD 106-6706

Meter

Setting

12VAC Power to Controller

50VAC Scale

1 and 3 on J3 or J2

12-18

24VAC Power to Right Module

50VAC Scale

8 on J3 and GROUND

22-28

120 VAC Power

250VAC Scale

11 on J3 and GROUND

110-125

120 VAC Power to Blowers

250VAC Scale

12 on J3 and GROUND

110-125

24VAC Power to Full Vat High-Limit

50VAC Scale

9 on J3 and GROUND

22-28

Probe Resistance (Full Vat) *

R x 1000 OHMS 2 and 6 on J3 or 13 and 14 on J2

**

Probe Isolation

R x 1000 OHMS 6 on J1 or J3 and GROUND

***

High-Limit Continuity (Full Vat)

R x 1 OHM

9 on J3 and Wire 13C on Gas Valve

0

** See Probe Resistance Chart at end of chapter.

*** 5 mega-Ohms or greater.

Test

Pins

Results

*

* Disconnect 20-pin harness from controller before testing probe circuit.

1.4 Thermostats

Protector

®

series gas fryers have temperature probes located on the front centerline of each frypot. In

this type of thermostat, the probe resistance varies directly with the temperature. That is, as the
temperature rises, so does resistance, at a rate of approximately 2 ohms for every 1º F. Circuitry in
the computer monitors the probe resistance and controls burner firing when the resistance exceeds or
falls below programmed temperatures (setpoints).

Protector

®

series gas fryers are also equipped with a high-limit thermostat. In the event that the fryer

fails to properly control the oil temperature, the high-limit thermostat prevents the fryer from
overheating to the flash point. The high-limit thermostat acts as a normally closed power switch that
opens when exposed to temperatures above 425ºF to 450ºF (218ºC to 232ºC). The different types of
thermostats have different part numbers for CE and Non-CE models, and are not interchangeable.

1.5

Accessing Fryers for Servicing

DANGER

Moving a fryer filled with oil may cause spilling or splattering of the hot liquid. Follow
the draining instructions in Chapter 5 of the Protector

®

Series Gas Fryer Installation

and Operation Manual (P/N 819-6339) before attempting to relocate a fryer for
servicing.

1. Shut off the gas supply to the unit. Unplug the power cords. Disconnect the unit from the gas

supply.


2. Remove any attached restraining devices and relocate the fryer for service accessibility.

3. After servicing is complete, reconnect the unit to the gas supply, reattach restraining devices, and

plug in the electrical cords.