GAS COOKTOP INSTALLATION INSTRUCTIONS

2

Figure 2 – COUNTERTOP CUTOUT OPENING

to eliminate the risk of

burns or fire by reaching over heated
surfaces, cabinet storage space located
above the cooktop should be avoided. if
cabinet storage is provided, risk can be
reduced by installing a range hood that
projects horizontally a minimum of 5"
beyond the bottom of the cabinets.

A

Min.

Dimensions

J

is the Minimum

Distance Required Between

Rear of top Panel to Adjacent

Combustible Surfaces.

18" Min.

Clearance

30" Min. Clearance

Between the top

of the Cooking

Platform and

Unprotected Wood

or Metal

Cabinet

24"

13" Max. Depth

For Cabinet

installed Above

Cooktop.

Dimension

H

is the

Minimum Clearance

Required From Right

Side of top Panel to

Adjacent Combustible

Surface.

Dimension

K

is the

Minimum Clearance

Required From Left

Side of top Panel to

Adjacent Combustible

Surface.

Allow Dimension

L

Space Below

Cooktop for Piping and Electrical

Connections.

Note: (For 26" and 36" Models Only). the rear edge of opening

must be 1 ½" from rear face of base cabinet. if countertops are

ordered from a supplier other than cabinet supplier, the relation of

the cutout in relation to the rear of the cabinet shall be specified.

Model

H

J

K

L

26" Model

1"

½"

1"

8½"

30" Model

0"

2"

2"

8 1/8"

36" Model

1"

2½"

1"

8¼"