Manual 0-2871

4-11

SERVICE

5. Connect the volt/ohmmeter positive lead to the an-

ode (+) of the diode and the negative lead to the cath-
ode (-) of the diode for forward bias testing (refer to
following figure). A properly functioning diode will
conduct in the forward bias direction and indicate be-
tween 0.3 to 0.9 volts.

0.75

VR COM

A

A-00307

Anode

Cathode

Forward Bias

Diode Conducting

+

_

Diode Test Symbol

Testing Diode Forward Bias

6.

Reverse the meter leads across the diode for re-
verse bias testing (refer to following figure). A
properly functioning diode will block in the re-
verse bias direction and depending on the meter
function will indicate an open or “OL”.

7.

If a diode checks bad, replace the diode module.

8.

Reconnect all cables.

OL

VR COM

A

A-00306

Anode

Cathode

Reverse Bias

Diode Not Conducting

+

_

Testing Diode Reverse Bias

C. Diode Module Board Tests

WARNING

Disconnect primary power at the source before tak-
ing any resistance checks.

1. Input Diode Module Board Circuit Test

a.

Remove AC power. Refer to Appendix 5-A or 5-B,
Main Power Wiring diagram.

b. Check Input Diode for shorted input diode. With

an ohmmeter set on the diode range make the fol-
lowing checks from Main PC Board to Input Di-
ode:

Meter (+)

Meter (-)

Indication

E7

E1

Open

E1

E7

Diode Drop

E15

E1

Diode Drop

E1

E15

Open

E15

E7

Diode Drop *

E7

E15

Open

Input Diode PCB

* Indication can be twice

other indications.

c.

The meter should indicate a diode drop in one di-
rection and an open in the other direction for each
check. Replace the Input Diode Module Board if
the readings do not match the chart.

d. If Input Diode Module Board is shorted, make the

following checks with an ohmmeter at the Main
Contactor (W1):

Meter (+)

Meter (-) Indication

L1

T1

Open

L2

T2

Open

L3

T3

Open

If any test has resistance, then replace the Main Con-
tactor.