SUPER RUNNER SERIES GAS FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

1-3

AUSTRALIAN REQUIREMENTS:


To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory
regulations.

CE UNITS ONLY:


Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings
and Pilot Markings are listed in the table below:

MANIFOLD GAS PRESSURE

MODEL*

NOMINAL

HEAT INPUT-

Qn

(kW)

GAS TYPE

ORIFICE

SIZE (MM)

MBAR INCH

W.C.

ORIFICE

QTY/ COLOR

BURNER

MARKING

PILOT

MARKING

SR62 GM

37.5

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

5/BLUE
5/BLUE

5/RED

Blue
Blue

Red

26N
26N

16LP

SR52 GM

30

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

4/BLUE
4/BLUE

4/RED

Blue
Blue

Red

26N
26N

16LP

SR42 GM

26

G20
G25
G31

2.40
2.40
1.51

12,0
17,5
22,0

4,8
7,0
8,8

3/BLUE
3/BLUE

3/RED

Blue
Blue

Red

26N
26N

16LP

*SR prefix- Super Runner Series

*GM suffix- gas millivolt system with no electrical supply connections

required


NON-CE UNITS ONLY:


Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are
listed in the table below:

MODEL*

NOMINAL

HEAT INPUT-

Qn

(BTU)

GAS TYPE

ORIFICE

SIZE (MM)

MANIFOLD GAS

PRESSURE

(INCH W.C.)

ORIFICE

QUANTITY

PILOT

MARKING

SR62 GM

150

NAT

LP

2.53(#39)
1.51(#53)

4

11

5
5

26N

16LP

SR52 GM

120

NAT

LP

2.53(#39)
1.51(#53)

4

11

4
4

26N

16LP

SR42 GM

105

NAT

LP

2.80(#35)
1.70(#51)

4

11

3
3

26N

16LP

*SR prefix- Super Runner Series

*GM suffix- gas millivolt system with no electrical supply connections required

NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is
operating.


1.4

Connection to the Gas Supply Line

NOTE: The gas supply (service) line must be the same size or greater
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company
or supplier, or your local contractor for minimum supply line
requirements.

NOTE: If quick-disconnect supply lines or flex lines are used,
increase supply line size to ¾-inch (22-mm) or larger.


Propane Applications:

Proper Regulator Must Be Installed

Regulator

Propane Applications;

Proper Regulator Must Be Installed