Calibrate HLZ

Semi-annual

PR 10 S1

©McDonald’s Corporation · Planned Maintenance Manual · Revised July 2007

Page 1 of 1

Frymaster Heated Landing Zone (HLZ) Models HLZ

18, HLZ22

Semi-annual

PR 10 S1

Why

To ensure correct holding temperature and accuracy of computer controls

Time required

20 minutes to prepare

10 minutes to complete

Time of day

During low-volume times

For 24-hour restaurants: During low-volume times

Hazard icons

Tools and supplies

Pyrometer with dual

male connectors

Procedure

1

Make sure HLZ is clean and at
proper operating temperature.
Make sure the HLZ is clean
and has been turned on for at
least 20 minutes. The display
should read “REdY”.

2

Plug pyrometer connector into
“AIR” receptacle on HLZ.

The HLZ is hot.

3

Read and compare air
temperatures.
Wait 3 minutes for the py-
rometer readout to stabilize.

Press the heater temperature
switch once to display the
HLZ air temperature readout.

Compare the two temperature
readings. If the two tempera-
tures are more than 15°F
(9°C) apart, contact your
Factory-Authorized Service
Center.

4

Plug pyrometer connector into
“PLATE” receptacle on HLZ.

5

Read and compare plate
temperatures.
Wait 3 minutes for the py-
rometer readout to stabilize.

Press the heater temperature
switch once to display the
HLZ plate temperature read-
out.

Compare the two temperature
readings. If the two tempera-
tures are more than 10°F
(5°C) apart, contact your
Factory-Authorized Service
Center.