4 connecting to other equipment – Furuno GP-320B User Manual

Page 12

Advertising
background image

4

Connecting to other equipment

Remove the connector from the antenna cable and attach crimp-on lugs or similar terminals
to the cable’s cores. Connect the cores to the junction box as below.

Antenna Cable
10 m

non-NavNet equipment

RS-422*

1

input for radar/plotter

Correction data from GR-80
output in RS-422 format

12-24 VDC*

2

(Input current: 105-55 mA)

NMEA 0183 Ver. 2.0

*1: RS-422 signal can

be received by using
current loop.

1
2
3
4
5
6
7

WHITE

BLACK

YELLOW

JUNCTION BOX

GREEN

RED

BLUE

Drain Wire

1
2

3
4

Fuse 0.5 A

RD-A
RD-B

TD-A
TD-B

Switchboard breaker

*2: Supply from breaker on switchboard


Note 1:
When connecting FURUNO DGPS beacon receiver GR-80 to this unit, set it as

follows:
Byte Format, 8-6; First Bit, LSB; Parity Bit, None; Stop Bit, 1; Bit Rate, 8.

Note 2: The signal ground and frame ground are separated, however the power line is not

isolated. Therefore, do not connect the signal ground to the frame ground when
other equipment is connected to a positive ground battery.

Note 3: WAAS function is inoperative when wiring as shown above.

Advertising