30"/36" drop-in electric cooktops, Professional, gallery & frigidaire, Drop-in cooktops – FRIGIDAIRE FGEC3665K User Manual

Page 2: Callouts must be charted per individual model)

Advertising
background image

30"/36" Drop-In Electric Cooktops

(Callouts MUST be charted per individual model).

Professional, Gallery & Frigidaire

FRIGIDAIRE

USA

Electrolux Major Appliances, North America

250 Bobby Jones Expressway

Martinez, GA 30907

1-800-FRIGIDAIRE

frigidaire.com

CANADA

Electrolux Canada Corporation

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

FGEC3665K 04/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Specifications

subject to change.

Drop-In Cooktop Specifications

Product Shipping Weight (approx.) – 65 Lbs.

Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt, 60 Hertz

AC only electrical supply with ground required on separate circuit

fused on both sides of line.

Connected Load (kW Rating) @ 240 / 208 Volts = 9.6 /7.2 kW

Amps @ 240 / 208 Volts = 40.0 / 35.0 Amps

Recommended Circuit Breaker – 40 Amps

Always consult local and national electric codes.

Allow 2" space beneath cooktop or optional platform to clear electrical

cable and allow space for installation of junction box on wall at back

of cooktop. Position center of junction box 10" inward from right side

of cooktop cutout, and 12" down from underside of countertop.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of cooktop and bottom

of unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than 36".

Allow 24" minimum clearance when bottom of wood or metal

overhead cabinet is protected by not less than 1/8" flame-retardant

millboard covered with not less than No. 28 MGS sheet steel, 0.015"

stainless steel, 0.024" aluminum or 0.020" copper.

Allow 2" minimum clearance between rear edge of cutout and nearest

combustible surface above countertop.

Allow 7-1/2" minimum clearance from edge of cooktop to nearest

combustible wall on either side of unit.

Installation of drawers beneath cooktop requires minimum 8"

clearance beneath countertop surface and assured clearance for

electrical connection.

To reduce risk of fire when using overhead cabinetry, install

range hood that projects horizontally a recommended minimum

of 5" beyond bottom of cabinets.

Electric Drop-In Cooktop model FGEC3665 is approved to be used

over any Frigidaire® Electric Single Wall Oven. (Refer to Electric

Cooktop Installation Over 30" / 27" Electric Single Wall Oven

Specifications page on web.)

Electric Drop-In Cooktop model FGEC3665 is approved to be used

in combination with any Frigidaire® 36" Downdraft Vent. (Refer to

model-specific Downdraft Vent product page on web for detailed

countertop preparation specifications.)

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Granite Countertop Installation Kit – (PN # 903061-9010).

Overall Product Dimensions

Product Cutout Dimensions

G - Cabinet

Opening

Width

Power Supply

Connection

Location

A – Width

B - Depth

C - Height

D - Width

E - Depth

F - Height

36-3/4"

21-1/2"

2-3/4"

35-5/8" min.

36-1/8" max.

20-1/4" min.

20-1/2" max.

5" min.

36" min.

Rear Right

Drop-In Cooktops

FGEC3665K S / W/B

36" Electric