30"/36" drop-in gas cooktops, Professional, gallery & frigidaire, Drop-in cooktops – FRIGIDAIRE Gallery FGGC3665K User Manual

Page 2: Callouts must be charted per individual model)

Advertising
background image

Drop-In Cooktops

FGGC3665K S / W/B

36" Gas

FRIGIDAIRE

USA

Electrolux Major Appliances, North America

250 Bobby Jones Expressway

Martinez, GA 30907

1-800-FRIGIDAIRE

frigidaire.com

CANADA

Electrolux Canada Corporation

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-800-265-8352

frigidaire.ca

FGGC3665K 04/09

© 2009 Electrolux Home Products, Inc.

Printed in the U.S.A.

Specifications

subject to change.

Drop-In Cooktop Specifications

Product Shipping Weight (approx.) – 70 Lbs.

Voltage Rating – 120V / 60 Hz / 15 Amps

For use on adequately wired 120V, dedicated circuit having 2-wire

service with a separate ground wire. Appliance must be grounded

for safe operation.

Amps @ 120 Volts = 1.0 Amps

Always consult local and national electric and gas codes.

Recommended location for grounded 120V outlet is on rear wall in an

8" wide by 10" high area, positioned 22" above floor surface and 4"

from right side of cooktop centerline. Access to underside of cooktop

and junction box must be provided for inspection and service.

Cooktop ships with 3/4" factory regulator.

LP Gas conversion kit supplied.

Overhead cabinetry should not exceed a 13" maximum depth.

Allow 30" minimum clearance between top of cooktop and bottom

of unprotected wood or metal overhead cabinetry.

Absolute minimum horizontal distance between overhead cabinets

installed to either side of appliance must be no less than 36".

Allow 24" minimum clearance when bottom of wood or metal

overhead cabinet is protected by not less than 1/8" flame-retardant

millboard covered with not less than No. 28 MGS sheet steel, 0.015"

stainless steel, 0.024" aluminum or 0.020" copper.

Allow 2-1/2" minimum distance between rear edge of cutout and

nearest combustible surface above countertop.

Allow 7" minimum clearance from edge of cooktop to nearest

combustible wall on either side of unit.

Installation of drawers beneath cooktop requires minimum 8"

clearance beneath countertop surface and assured clearance for

gas and electrical connections.

To reduce risk of fire when using overhead cabinetry, install

range hood that projects horizontally a recommended minimum

of 5" beyond bottom of cabinets.

Gas Drop-In Cooktop model FGGC3665K is approved to be used

over any Frigidaire® Electric Single Wall Oven. (Refer to Gas Cooktop

Installation Over 30" / 27" Electric Single Wall Oven Specifications

page on web.)

Gas Drop-In Cooktop model FGGC3665K is approved to be used

in combination with any Frigidaire® 36" Downdraft Vent. (Refer to

model-specific Downdraft Vent product page on web for detailed

countertop preparation specifications.)

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

Optional Accessories

Granite Countertop Installation Kit – (PN # 903103-9010).

30"/36" Drop-In Gas Cooktops

(Callouts MUST be charted per individual model).

Professional, Gallery & Frigidaire

Overall Product Dimensions

Product Cutout Dimensions

G - Cabinet

Opening

Width

Power Supply

Connection

Location

Gas Supply

Connection

Location

A – Width

B - Depth

C - Height

D - Width

E - Depth

F - Height*

36"

21-1/2"

4-5/8"

32-3/4" min.

33" max.

19" min.

19-3/8" max.

8" min.

36" min.

Right Rear

Right Rear

Advertising
This manual is related to the following products: