10. Reconnect the unit to the electrical power supply, and verify that the pump is functioning

correctly (i.e., when a filter handle is placed in the ON position, the motor should start and there
should be strong suction at the intake fitting and outflow at the rear flush port.)

11. When proper operation has been verified, reinstall the back panels and the filter pan and lid.

12. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply to

return the fryer to service.


1.9.3 Replacing the Filter Transformer or Filter Relay

Disconnect the fryer from the electrical power supply. Remove the left controller from the fryer to
expose the interior of the left component box. The filter transformer and relay are located as shown
in the illustration below. NOTE: The right component box is identical to the left except that the
filter transformer and relay are not present.

Filter

Relay

Filter

Transformer

Dual-vat configuration illustrated. In full-vat units, left filter handle is not present.