Frymaster 2836 User Manual

Page 17

Advertising
background image

1-12

1.12 Electric Interface Board Diagnostic Chart

The following diagram and charts provide ten quick system checks that can be performed using
only a multimeter.



Meter Setting

Test

Pin

Pin Results

12 VAC Power

50 VAC Scale

1 of J2

3 of J2

12-16 VAC

24 VAC Power

50 VAC Scale

2 of J2

Chassis 24-30

VAC

*Probe Resistance

R X 1000 OHMS

11 of J2

12 of J2 See Chart

Hi-Limit Continuity

R X 1 OHMS

7 of J2

4 of J2

0 - OHMS

Latch Contactor Coil

R X 1 OHMS

8 of J2

Chassis 3-10

OHMS

Heat Contactor Coil

R X 1 OHMS

9 of J2

Chassis 18-25

OHMS


*Disconnect 15-Pin harness from the computer/controller before testing the probe circuit.

Note: The sealed relays are
replaceable. If a relay fails,
the replacement part number
is 807-3932.

Diagnostic LED Legend

CMP indicates power from 12V transformer
24

indicates power from 24V transformer

HI

(RH) indicates output (closed) from right latch
relay

HI

(LH) not applicable to Ultimate Electric fryers

HT

(RH) indicates output from right heat relay

HT

(LH) not applicable to Ultimate Electric fryers

AL

(RH) indicates output (open) from right latch
relay

AL

(LH) not applicable to Ultimate Electric fryers

1

2

3

4

5

6

8

7

9

10

11

12

13

14

15

1

2

3

4

5

6

7

8

9

10

11

12

1

2

3

4

5

6

7

8

9

10

11

12

K1

K2

K 3

K4

Advertising